Search Header Logo
Copy of Unit: 205, Requirements of Cold Water Supplies into Domestic Dwellings 2

Copy of Unit: 205, Requirements of Cold Water Supplies into Domestic Dwellings 2

Assessment

Presentation

Construction

Vocational training

Practice Problem

Medium

Created by

Patrick McGinn

Used 1+ times

FREE Resource

24 Slides • 17 Questions

1

media

2

media

3

Multiple Choice

Which of the following is the minimum required depth for a communication pipe in a domestic cold water supply system?

1

250mm

2

750mm

3

1350mm

4

2000mm

4

media

5

Multiple Choice

Which of the following statements about water meters is correct?

1

Internal meters do not require cross bonding for safety.

2

Boundary meter boxes are only used for gas meters.

3

Internal meters need to be cross bonded for safety.

4

External meters are installed inside the building.

6

media

7

media

8

Multiple Choice

According to the Water Regulations, where should a stop valve be located inside a building?

1

Below floor level, far from the point of entry

2

Above floor level, as near as possible to the point of entry

3

Outside the building, near the water main

4

Anywhere inside the building

9

media

10

Multiple Select

Select all correct statements about stop valves and DOVs.

1

Stop valves create a watertight seal by pushing a washer against a seating.

2

If a stop valve jams, the entire valve must be replaced.

3

DOVs must be installed above the incoming stop valve and at every low point in the system.

4

DOVs use a spanner or key on the square drive to operate.

11

media

12

Fill in the Blanks

Type answer...

13

media

14

media

15

Multiple Choice

What are the two basic ways pressure can be created in plumbing systems?

1

By heating water and increasing its temperature

2

By fitting a pump or by the weight of water (the head)

3

By increasing the pipe diameter

4

By adding chemicals to the water

16

media

17

media

18

Multiple Choice

Which of the following factors can affect both pressure and flow in a plumbing system?

1

Daily demand

2

Location

3

Blockages

4

All of the above

19

media

20

Fill in the Blanks

Type answer...

21

media

22

Multiple Select

Select all the statements that are true about a direct cold water system.

1

All cold water is supplied directly to each outlet at mains pressure.

2

Old houses may have 20mm MDPE copper or lead mains.

3

Precautions against backflow are not necessary.

4

The system uses low pressure.

23

media

24

media

25

Multiple Choice

Which of the following is NOT a feature of a direct water system?

1

Stored water is present

2

Hot and cold water are directly off mains

3

No water is stored at all

4

Combination boiler is used

26

media

27

media

28

Multiple Select

Which of the following statements about indirect water systems is/are correct?

1

Cold water is taken via the rising main to a storage cistern

2

Most cold water outlets are fed with low pressure

3

Kitchen sink is mains-fed

4

All outlets receive potable water

29

media

30

Fill in the Blanks

Type answer...

31

media

32

media

33

Multiple Choice

According to the Water Regulations, what is the minimum capacity required for a cold water storage cistern if supplying both hot and cold water?

1

100-150 liters

2

230-250 liters

3

50-100 liters

4

150-200 liters

34

media

35

Multiple Choice

Which of the following is a benefit of rainwater harvesting for householders?

1

It increases the use of mains water

2

It reduces the pressure on mains water resources

3

It eliminates the need for water storage cisterns

4

It increases water wastage

36

media

37

media

38

Multiple Select

Which of the following are important requirements for installing rainwater and grey water systems?

1

Prevent contamination of wholesome water

2

Systems must be independent

3

Pipework must be identified properly

4

Systems must be connected to mains water

39

media

40

Fill in the Blanks

Type answer...

41

Multiple Choice

What are the minimum depth and diameter requirements for a communication pipe in a domestic cold water supply system?

1

750-1,350mm deep and 15mm diameter

2

500-1,000mm deep and 10mm diameter

3

1,500-2,000mm deep and 20mm diameter

4

250-500mm deep and 8mm diameter

media

Show answer

Auto Play

Slide 1 / 41

SLIDE