1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The code requirement for an adequate supply of potable running water is for ___________________.

safety and sanitation

protection of trap seals

water-cooled equipment

hydronic systems

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In occupancies where plumbing fixtures are installed for ________, hot water shall be required for bathing and washing purposes.

public use

commercial use

private use

daycare facilities

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Except as required in Sections 1610.0 and 1617.0, non-potable water systems shall have a _____________ with black uppercase lettering, with the words "CAUTION: NON-POTABLE WATER, DO NOT DRINK."

white background

blue background

green background

yellow background

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The primary reason for installing backflow prevention assemblies is to ________________________.

prevent excessive pressure

prevent mixing of hot and cold water

prevent pollution or contamination of the potable water supply

prevent scalding

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

All backflow devices or assemblies shall be tested by a __________________________.

licensed agent

representative from the Authority Having Jurisdiction

certified backflow tester

third-party certified agency

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Choose the answer you think is correct for the minimum height of the atmospheric vacuum breaker above the point specified.

Above all downstream piping for lawn sprinkler system atmospheric vacuum breakers: _________

1"

6"

12"

24"

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Backflow prevention devices installed in the water supply line to steam boilers shall be installed ________________________.

6 inches above the floor

6 inches above the boiler

12 inches above the floor

12 inches above the boiler

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?