Siemens Level 1 Electrical #2

Siemens Level 1 Electrical #2

12th Grade - University

19 Qs

quiz-placeholder

Similar activities

SA4 - HV & LV Electrical Protections

SA4 - HV & LV Electrical Protections

12th Grade

20 Qs

Harper-ELT140_Quiz02

Harper-ELT140_Quiz02

University

24 Qs

LCA Quiz

LCA Quiz

KG - Professional Development

17 Qs

COD1101_Midterm Exam

COD1101_Midterm Exam

University

22 Qs

Electric 2 Week 1

Electric 2 Week 1

University

15 Qs

DSL-204 Chap 37 Anti-Lock Braking, Veh Stability, Collision Sys.

DSL-204 Chap 37 Anti-Lock Braking, Veh Stability, Collision Sys.

University

20 Qs

Siemens Level 1 Electrical #1

Siemens Level 1 Electrical #1

University - Professional Development

20 Qs

IoT Sensors and Devices

IoT Sensors and Devices

University

20 Qs

Siemens Level 1 Electrical #2

Siemens Level 1 Electrical #2

Assessment

Quiz

Professional Development

12th Grade - University

Medium

Created by

Chris Jones

Used 309+ times

FREE Resource

19 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

To measure electrical …

current, the ammeter must be in series with the current path.

voltage, you must disconnect a component lead or a wire before you connect the voltmeter.

resistance, connect the ohmmeter across the component without disconnecting the supply voltage.

resistance, the ohmmeter must be placed in series with the component.

none of the above.

2.

MULTIPLE SELECT QUESTION

2 mins • 1 pt

Media Image

As shown below, a through-beam sensor with fiber-optic cable is used to detect parts on a work piece carrier. If no part is present, the sensor sends a high signal to the PLC. Which of the following statements about the operation of the sensor are correct? Two answers are correct.

Power failure of the light emitter is evaluated as “work piece not present”.

The presence of the work piece can only be detected if the light beam is visible.

It is not possible to detect completely transparent work pieces.

Fiber-optic cable break on the receiver side is evaluated as “work piece not present”.

A broken fiber-optic cable at the light emitter is evaluated as “work piece present”.

3.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Media Image

An automotive application involves an inductive sensor that detects the crankshaft position to adjust the fuel control system. The result of a test measurement at the output of the sensor is shown below. The magnitude (Vpp) and rotational speed are …

≈ 1.2 V, 1000 r.p.m.

≈ 1.2 V, 3000 r.p.m.

≈ 12 V, 1200 r.p.m.

≈ 1.2 V, 12,000 r.p.m.

≈ 12 V, 300 r.p.m.

4.

MULTIPLE SELECT QUESTION

2 mins • 1 pt

Media Image

Which of the following statements about the functionality of the emergency lighting circuit, as shown below, are correct? Two answers are correct.

In the event of main power failure, the emergency lamp is not lighted.

The lamp will be connected to the storage battery as long as the relay remains de-energized.

As long as the main power is available, it energizes the relay coil.

Since the relay coil is energized, the N.C. contact is open and the emergency lamp is lighted.

In the event of main power failure, the secondary of the transformer keeps the battery charged through the rectifier.

5.

MULTIPLE SELECT QUESTION

2 mins • 1 pt

Media Image

Which statements about the mode of operation of a reflective light barrier shown below are correct? Two answers are correct.

If no object is present, the reflector must absorb the light emission.

The interruption of the light beam by an object causes the output of the sensor to switch.

Failure of the transmitter is evaluated as “object present”.

No voltage between BN(1) and BU(3) is evaluated as “no object present”.

An advantage is that both transparent and reflecting objects can be detected.

6.

MULTIPLE SELECT QUESTION

2 mins • 1 pt

Media Image

If an object were caught in the upward movement of the car window, stalling the motor, what effect would this have on the window control circuit for a car door shown below? Two answers are correct.

Increase in voltage drop across sensing resistor R

Decrease in motor current IMotor

Increase in motor current IMotor

Decrease in voltage drop across sensing resistor R

Decrease in Analog Output Signal

7.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Media Image

By looking at the given measuring results of the electrical circuit shown below, determine the type of failure in the circuit.

There is a short between A and B.

There is a short between B and GND.

There is a open between D and -Vs.

Between A and B is an open circuit.

Between A and + of Vs is an open circuit.