PRO
Authored by Lori Norrell
University
Used 58+ times

AI Actions
Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...
Content View
Student View
10 questions
Show all answers
1.
MULTIPLE CHOICE QUESTION
1 min • 1 pt
Some substances that are added to make water safe to drink may be harmful if used in the dialysis process. True or Flase
True
False
2.
MULTIPLE CHOICE QUESTION
1 min • 1 pt
Of the three components that make up dialysate, which one is in the greatest quantity?
Bicarb
Treated Water
Acid
3.
MULTIPLE CHOICE QUESTION
1 min • 1 pt
Which contaminant, if able to cross the dialyzer membrane, can cause hemolysis or bursting of the red blood cells?
Virus
Chlorine/Chloramine
Fluoride
Bacteria/Endotoxin
4.
MULTIPLE CHOICE QUESTION
1 min • 1 pt
There are at least two carbon filtration devices in a dialysis water treatment system located before the PRO. The first carbon filtration filter is called the:
Resister/Resistivity tank
Utilization tank
Worker tank
Conduction tank
5.
MULTIPLE CHOICE QUESTION
1 min • 1 pt
According to AAMI standards, what is the minimum length of time water must be exposed to carbon?
10-minute EBCT
30-minute EBCT
8 hours EBCT
24 hours EBCT
6.
MULTIPLE CHOICE QUESTION
1 min • 1 pt
The carbon filtration device removes what contaminate from the water?
Calcium and Magnesium
Chlorine
Carbon and Carbonic Acid
Copper and Iron
7.
MULTIPLE CHOICE QUESTION
1 min • 1 pt
The first Total Chlorine test must be performed:
Before turning the RO on for the day
Before the last patient treatment ends
Before initiation of the first patient treatment
Within the first hour of first patient shift