Search Header Logo

unit 14 automatic controls

Authored by Ken Hassinger

Life Skills

10th - 12th Grade

Used 18+ times

unit 14 automatic controls
AI

AI Actions

Add similar questions

Adjust reading levels

Convert to real-world scenario

Translate activity

More...

    Content View

    Student View

23 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A low pressure control has a "high event" and a "differential" setting. The technician wants the system to turn on at 28 psig and shut down at 2 psig. What would be the proper settings?

high event: 28 psig, differential: 2 psig

high event: 2 psig, differential: 2 psig

high event: 28 psig, differential: 26 psig

high event: 2 psig, differential: 28 psig

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

If the suction pressure of a system is 60 psig and the oil pump outlet is 85 psig, what is the net oil pressure?

60 psig

25 psig

85 psig

145 psig

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where would a water regulating valve that is controlling head pressure be installed?

water circuit at inlet of condenser

discharge line at outlet of compressor

suction line

liquid line close to the condenser

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When a water regulating valve is used to control the head pressure of a water-cooled system, the valve's spring is acting against which pressure to modulate the water flow?

head pressure of the system

water pressure

suction pressure

atmospheric pressure

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The purpose of a heat anticipator is to ____.

anticipate a sudden rise in temperature

keep the thermostat warm

reduce the temperature swing of a conditioned space

ensure that the system transformer does not overheat

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The difference between system overshoot and system lag is called ____.

room temperature

temperature rise

temperature drop

temperature swing

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following can cause a compressor's internal overload to open?

system undercharge

system overcharge

faulty starting component(s)

all of the above

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?