2365-L3 625

2365-L3 625

Professional Development

11 Qs

quiz-placeholder

Similar activities

27-04-20

27-04-20

KG - Professional Development

10 Qs

VLOCITY QUIZ

VLOCITY QUIZ

Professional Development

10 Qs

Snakes

Snakes

4th Grade - Professional Development

16 Qs

Global Safety Day 2022

Global Safety Day 2022

1st Grade - Professional Development

10 Qs

Guess the logo

Guess the logo

Professional Development

13 Qs

Gran Turismo Quiz

Gran Turismo Quiz

KG - Professional Development

6 Qs

AIC Lab - Viva

AIC Lab - Viva

Professional Development

15 Qs

So what do you know?

So what do you know?

University - Professional Development

11 Qs

2365-L3 625

2365-L3 625

Assessment

Quiz

Other

Professional Development

Medium

Created by

kevin barnett

Used 4+ times

FREE Resource

11 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

identify the type of emergency light fitting the remains lit continuously
sustained
contained
maintained
non maintained

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

identify the rating of an RCD used for additional protection for buried cables in walls.
100mA
20mA
13A
30mA

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

when applying DIVERSITY to discharge lighting (such as fluorescent lamps), identify the multiplication factor that should be applied to the lamp wattage
2
1.8
10
5.5

4.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

identify the rated short-circuit capacity of a BS88-6 device at 240v, as detailed in the On Site guide
16kA
33kA
16.5kA
31.5kA

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

how can long runs of pvc conduit be installed to reduce the prospect of distorting and buckling due to large changes in ambient temperature.
greater distances between saddles
pvc conduit must not be installed in these environments
regular through-boxes are used throughout the run
use expansion couplers

6.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

identify the maximum 'measured' Zs value allowed for a type B 16A circuit breaker to BSEN60898, as detailed in the On Site guide
3.5 ohms
1.09 ohms
2.2 ohms
1.58 ohms

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

if an overcurrent occurs in an otherwise healthy circuit, this would be called ........
an open circuit
an earth fault
a short circuit
an overload