#5 EPA 608 Type III

#5 EPA 608 Type III

11th Grade - Professional Development

25 Qs

quiz-placeholder

Similar activities

EPA Type 1

EPA Type 1

12th Grade

20 Qs

EPA 608 - TYPE 1

EPA 608 - TYPE 1

9th - 12th Grade

20 Qs

EPA 608 - TYPE 1

EPA 608 - TYPE 1

9th - 12th Grade

27 Qs

Core quiz 1 August 15 - August 18

Core quiz 1 August 15 - August 18

Professional Development

20 Qs

Pre-Test

Pre-Test

1st Grade - University

20 Qs

#1 EPA 608 Type III

#1 EPA 608 Type III

11th Grade - Professional Development

25 Qs

HAC-101 Chap 59 HVAC System Diagnostic (Diesel) Test A

HAC-101 Chap 59 HVAC System Diagnostic (Diesel) Test A

University

20 Qs

#3 EPA 608 Type I

#3 EPA 608 Type I

11th Grade - Professional Development

25 Qs

#5 EPA 608 Type III

#5 EPA 608 Type III

Assessment

Quiz

Other

11th Grade - Professional Development

Easy

Created by

Mike Conway

Used 269+ times

FREE Resource

25 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A chiller with a charge of 200 pounds has passed the initial verification leak test. When must a follow ­up verification test be conducted?

The same day.

The next day.

Within 10 days.

Within 30 days.

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What evacuation level must technicians recover refrigerant to before disposing a low-pressure appliance?

0 psig

15 inches of Hg vacuum

25 inches of Hg vacuum

25 mm of Hg absolute

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A rupture disc on a recovery vessel for low-pressure refrigerants relieves at;

5 psig.

10 psig.

15 psig.

20 psig.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

On low-pressure chillers, moisture most frequently enters the refrigerant system through;

air leaks in the rupture disc assembly.

tube leaks in the evaporator.

leaks from areas with gaskets or fittings.

leaks from the charging service valve.

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

How long must owners and operators of low-pressure chillers using HCFC refrigerant keep records of leak inspections, initial verification, and follow-up verification tests?

2 years

3 years

5 years

Life of the appliance

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Starting in 2019, what is the leak rate threshold for comfort cooling appliances with a full charge of 50 or more pounds?

5%

10%

20%

30%

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where is the lowest access point on a low-pressure centrifugal air-conditioning appliance?

Evaporator charging valve.

Condenser service valve.

Compressor cooler jacket.

Purge unit exhaust port.

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?