Int Pneumatics LAP 2- Air Logic

Int Pneumatics LAP 2- Air Logic

Professional Development

8 Qs

quiz-placeholder

Similar activities

Kuiz Sambung Lagu Tradisional Brunei

Kuiz Sambung Lagu Tradisional Brunei

8th Grade - Professional Development

10 Qs

Sandvik Environmental Expo 2022 - Sesi 3

Sandvik Environmental Expo 2022 - Sesi 3

8th Grade - Professional Development

10 Qs

Friday Fun!

Friday Fun!

Professional Development

10 Qs

BUGÜN NE ÖĞRENDİM ? / 1 MART 2024

BUGÜN NE ÖĞRENDİM ? / 1 MART 2024

Professional Development

11 Qs

Post Test MCU SCB

Post Test MCU SCB

Professional Development

10 Qs

Cabaran Persahabatan 2021 by Putri

Cabaran Persahabatan 2021 by Putri

Professional Development

10 Qs

Pondok K3luarga - Kebakaran

Pondok K3luarga - Kebakaran

Professional Development

10 Qs

Int Pneumatics LAP 2- Air Logic

Int Pneumatics LAP 2- Air Logic

Assessment

Quiz

Other

Professional Development

Practice Problem

Hard

Created by

Shannon Honeycutt

Used 14+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

8 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

For shifting, externally air piloted pneumatic DCVs use:

Remote air pressure

Solenoids

Levers

Manual overrides

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In an air logic sequence circuit, the ________________ valves acts as a limit switch.

Cam

Shuttle

Unloading

Counterbalance

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Shuttle valves are used in air logic circuits to _________________

Provide OR logic

Latch in spring offset externally piloted DCV’s

Provide an output when either of two input signals are applied

All of the answers are correct

None of the answers are correct

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

An advantage of air logic over electrical controls is that it ______________

Is safe in places where electrical systems could cause fire or explosion

Is less expensive for four or more relays

Has a faster signal

All of the answers are correct

None of the answers are correct

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

To unlatch a pneumatic seal-in circuit, air logic circuits _____________-

Use a push button valve

Shut off the pneumatic supply

Vent the air pilot of the DCV with the cam valve

Use a shuttle valve

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A shuttle valve exhausts an air pilot of a DCV when _____________

One input is less than the other input

Both inputs are pressurized

Both inputs are vented

None of the answers are correct

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Air logic is popular in the food processing industry because ________________-

The exhaust air can be used to eliminate odors

Of the moisture present during cleanup

It is less expensive than a PLC when more than four relays are needed

It is cleaner than electricity

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?