Search Header Logo

#3 EPA 608 Type I

Authored by Griselda Valerio

Other

11th Grade - Professional Development

Used 10+ times

#3 EPA 608 Type I
AI

AI Actions

Add similar questions

Adjust reading levels

Convert to real-world scenario

Translate activity

More...

    Content View

    Student View

25 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A very large refrigerant leak can cause suffocation because refrigerants;

smell strong and make breathing difficult.

are lighter than air and cause dizziness.

are heavier than air and displace oxygen.

sting the nose and cause sneezing.

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

Equipment which is used to recover CFC, HCFC, and HFC refrigerant from small appliances for the purpose of disposal must meet what standard?

Recover 95% or the refrigerant whether or not the compressor is operative.

Recover 80% of the refrigerant with an inoperative compressor and 90% of the refrigerant with an operative compressor.

Recover 90% of the refrigerant with an inoperative compressor and 80% of the refrigerant with an operative compressor.

Recover 75% of the refrigerant within 5 minutes.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

For which of the following refrigeration systems/appliances would it be permissible to use a passive recovery device for recovery of CFCs, HCFCs, and HFCs?

A centrifugal air conditioner

A reciprocating liquid chiller

A single compressor, large commercial walk-in freezer

A domestic refrigerator

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

If a large leak of refrigerant occurs, such as from a filled cylinder in an enclosed area, what action should be taken when no self-contained breathing apparatus is available?

Use butyl lined gloves and try to stop the leak.

Use a leak detector to locate the leak and try to stop the leak.

Vacate and naturally ventilate the spill area.

Make sure the unit is de-energized, close the service valves and try to stop the leak.

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

Permanent safety markings are NOT required on which of the following areas on household refrigerators using HC refrigerants?

On or near any evaporators and near any exposed refrigerant tubing.

Near the machine compartment.

On the inside of the refrigerator door.

On the exterior of the refrigerator.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

What can CFC and HCFC refrigerants decompose into at high temperatures (e.g. open flames, glowing metal surfaces, etc.)?

Boric and chromic acids

Sulfuric and phosphoric acids

Hydrochloric and hydrofluoric acids

Phosphoric and dodecylbenzenesulfonic acid

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the approximate pressure of a storage cylinder of recovered R-404A that does not contain any non-condensable impurities and is stored in a room where the temperature is 80°F?

68 psig

72 psig

174 psig

288 psig

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?