Article 210 Questions 31-40

Article 210 Questions 31-40

9th Grade

10 Qs

quiz-placeholder

Similar activities

quizz final tension

quizz final tension

6th - 9th Grade

14 Qs

Continental Drift & Plate Tectonics

Continental Drift & Plate Tectonics

9th Grade

14 Qs

Electricity

Electricity

9th - 10th Grade

10 Qs

Électricité et magnétisme

Électricité et magnétisme

5th - 9th Grade

15 Qs

PRETEST

PRETEST

9th Grade

10 Qs

Electricity Week 1 Review

Electricity Week 1 Review

9th Grade

13 Qs

Testing Quiz Bee Simulation

Testing Quiz Bee Simulation

7th - 10th Grade

10 Qs

Electricity and Circuits

Electricity and Circuits

6th - 9th Grade

10 Qs

Article 210 Questions 31-40

Article 210 Questions 31-40

Assessment

Quiz

Science

9th Grade

Medium

Created by

Philip Strassel

Used 5+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

31. All 15A or 20A, 120V branch circuits that supply outlets or devices in dwelling unit kitchens, family rooms, dining rooms,living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, hallways, laundry areas, or similar rooms or areas shall be AFCI protected by a listed arc-fault circuit interrupter.

(a)True
(b)False

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

32. Where branch-circuit wiring in a dwelling unit is modified, replaced, or extended in any of the areas specified in 210.12(A), the branch circuit must be protected by a ______.

(a) listed combination AFCI located at the origin of the branch circuit
(b)listed outlet branch-circuit AFCI located at the first receptacle outlet of the existing branch circuit
(c) GFGI circuit breaker or receptacle
(d)a or b

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

33. The recommended maximum total voltage drop on branchcircuit conductors is ______ percent.

(a) 2
(b)3
(c) 4
(d)6

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

34. Where a branch circuit supplies continuous loads, or any combination of continuous and noncontinuous loads, the rating of the overcurrent device shall not be less than the noncontinuous load plus 125 percent of the continuous load.

(a)True
(b)False

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

35. A single receptacle installed on an individual branch circuit shall have an ampere rating not less than that of the branch circuit.

(a)True
(b)False

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

36. The total rating of utilization equipment fastened in place shall not exceed ______ percent of the branch-circuit ampere rating where lighting units and cord-and-plug-connected utilization equipment are supplied.

(a) 50
(b)75
(c)100
(d)125

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

37. ________in dwelling units shall supply only loads within that dwelling unit or loads associated only with that dwelling unit.

(a)Service-entrance conductors
(b)Ground-fault protection
(c) Branch circuits
(d) none of these

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?