Code Quiz 2

Code Quiz 2

KG

15 Qs

quiz-placeholder

Similar activities

Personal Financial Literacy

Personal Financial Literacy

3rd Grade

15 Qs

SALARIES AND WAGES

SALARIES AND WAGES

10th - 11th Grade

10 Qs

KOE034: Sensors and Instruments

KOE034: Sensors and Instruments

Professional Development

11 Qs

Module 10

Module 10

University

10 Qs

MH Article 230 41-50

MH Article 230 41-50

10th Grade

10 Qs

17-2 The Transfer of Heat

17-2 The Transfer of Heat

6th Grade

20 Qs

Grade 8 Comparing Quantities

Grade 8 Comparing Quantities

8th Grade

10 Qs

Inequality

Inequality

6th Grade

20 Qs

Code Quiz 2

Code Quiz 2

Assessment

Quiz

Mathematics

KG

Hard

Created by

I Collins

Used 1+ times

FREE Resource

15 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

The grounding electron conductor of a grounded 400 amp AC system , when connected to a made electrode and which is the sole connection to the grounding electrode, is permitted to be a _________.

#6 Copper

#4 Copper

#2 Copper

#1/0 Copper

2.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

A piece of electronic equipment is required to be connected with an isolated equipment grounding conductor. The design is such that the metal raceway containing the supply conductors is to be isolated from the equipment enclosure, but the raceway contains an insulated copper equipment grounding conductor. Which of the following best describes Code requirements for this installation?

The raceway shall not be isolated from the equipment.

The isolation fitting may be located at the panelboard.

The isolation fitting may be anywhere in the conduit run.

The isolation fitting must be located at the equipment enclosure.

3.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

An electrically operated organ shall have both the generator and motor frames grounded or _________.

the generator and motor shall be effectively insulated from ground and from each other.

the generator and motor shall be effectively insulated from ground.

the generator shall be effectively insulated from ground and from the motor driving it

both the generator and motor shall have double insulation.

4.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

In communication circuits the bonding together of all separate electrodes ___________.

shall not be permitted.

shall be permitted with a minimum size jumper #4

Shall be permitted with a minimum size jumper #6

Shall be permitted with a minimum size jumper #8

5.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

Which of the following is NOT a true statement concerning an equipment grounding conductor?

Under certain conditions, equipment grounding conductors may be required to be larger than circuit conductors.

Under certain conditions, equipment grounding conductors may be run parallel.

One size of equipment grounding conductors shall be increased to compensate for voltage drop.

One equipment grounding conductor may serve multiple circuits

6.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

On a 4-wire delta-connected secondary where the midpoint of one phase is grounded to supply lightning and similar loads, the phase conductor having the higher voltage to ground shall be identified by _________.

I. Durably and permanently marked

II. An outer finish that is orange in color

III. Other effective means

I only

II Only

III Only

I, II, and III

7.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

The neutral of a solidly grounded neutral system shall be permitted to be grounded at more than one point for _________.

I. Services

II. direct buried portions of feeders employing a bare copper neutral

I. Only

II. Only

III Only

I, II, and III

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?