OREDE-P RGTSU Natural Gas Sent Out System

OREDE-P RGTSU Natural Gas Sent Out System

Professional Development

7 Qs

quiz-placeholder

Similar activities

Personal Financial Management

Personal Financial Management

Professional Development

10 Qs

Sprinkler System

Sprinkler System

Professional Development

11 Qs

Engine Lubrication

Engine Lubrication

Professional Development

10 Qs

formation SST-Prévention

formation SST-Prévention

Professional Development

11 Qs

Awareness ISO/IEC 27701: 2019

Awareness ISO/IEC 27701: 2019

Professional Development

10 Qs

Nodejs: Rate Limiting and File Upload

Nodejs: Rate Limiting and File Upload

Professional Development

10 Qs

IPPS CPEA Pre-Test Quiz 2020

IPPS CPEA Pre-Test Quiz 2020

Professional Development

10 Qs

Virtual Original Medicare Quiz

Virtual Original Medicare Quiz

Professional Development

11 Qs

OREDE-P RGTSU Natural Gas Sent Out System

OREDE-P RGTSU Natural Gas Sent Out System

Assessment

Quiz

Professional Development

Professional Development

Practice Problem

Easy

Created by

Nur Deyana

Used 6+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

7 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

HIPPS stand for__________________

High Intervene Pressure Protection System

High Integrity Pressure Protection System

High Interlock Pressure Protection System

High Intergrated Pressure Protection System

2.

MULTIPLE SELECT QUESTION

45 sec • 1 pt

Natural Gas Sent Out System it comprises of the following_____________, ____________and ____________

Export Gas Metering

HIPPS

Pig Launching and Receiving System

BOG Compressor

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The sub-sea export gas pipeline is a 30” carbon steel pipeline

True

False

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the type of flow meter of the metering?

Ultrasonic

Turbine Meter

Rota Meter

Retro Magnetic Meter

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

•In case of ESD MOV-2611 and MOV-2613 shall be left open to enable metering skid depressurization.

True

False

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is primary protection provider by HIPPS

Low pressure of the pipeline and downstream facilities

Medium pressure of the pipeline and downstream facilities

Over pressure of the pipeline and downstream facilities

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A __________ direction pig launcher/receiver is provided to allow pigging of the subsea gas pipeline from Jetty to shore and vice versa

Single

Dual

Triple

Discover more resources for Professional Development