INSTRUMENT INSTALLATION AND MAINTENANCE

Quiz
•
Professional Development
•
University
•
Hard
Yong Shahriah
Used 6+ times
FREE Resource
8 questions
Show all answers
1.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
Field-level buses can be grouped in many categories. Which bus is used with proximity switches, pushbuttons, motor starters, and other simple devices?
Device Bus
Sensor Bus
Fieldbus
Profibus DP
2.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the meaning of HART
Highway Addressable Remote Transformer
Highway Addressable Remote Transmitter
Highway Addressable Remote Thermometer
Highway Addressable Remote Transducer
3.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
FOUNDATION fieldbus is covered by standards from three major organizations EXCEPT
ISO 9001:2000
ANSI/ISA 50.02
CENELAC EN50170:1996/A1
IEC 61158
4.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
Which one of a sentence below related to Fieldbus?
Sensor buses are common in discrete manufacturing.
Multiple field-level networks, with different types of buses to meet different needs.
Provide highly reliable two-way communications between "smart" devices and systems in time-critical applications.
Buses are designed to meet the needs of more complex devices, often in fast-moving discrete operations requiring short, fast communications.
5.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
There are several types of wires are used in Fieldbus wiring. Which one of a sentence below related to Type C Wire?
Multiple Twisted Pair Without Shield, #26 AWG (0.13 mm2) , 400 m (1312ft)
Multiple Twisted Pair Without Shield, #22 AWG (0.32 mm2), 400 m (1312ft)
Multiple Twisted Pair Without Shield, #26 AWG (0.13 mm2) , 200 m (656ft)
Multiple Twisted Pair With Overall Shield, #26 AWG (0.13 mm2), 400 m (1312ft)
6.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
The Fieldbus communications model consists of three layers EXCEPT
The User Layer
The Network Layer
The Data Link & Application Layer
The Physical Layer
7.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
A segment has 4000 feet (1220 meters) of type A shielded twisted pair wire and 200 feet (61 meters) of type D non-shielded, non-twisted pair. What is the sum of the ratios for this 2 mixing wire?
0.64 or 64%
0,74 or 74 %
0,84 or 84 %
0.94 or 94 %
8.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is IEC 61511?
An international safety standard issued by the International Electrotechnical Commission.
An international safety standard issued by the International Electronic Commission.
An international safety standard issued by the International Electrical Commission.
An international safety standard issued by the International Electromechanical
Commission
Similar Resources on Wayground
10 questions
Perencanaan Usaha Kerajinan Bahan Limbah Bangun datar (PKWU)

Quiz
•
12th Grade - University
10 questions
WildChina Education - Education Quiz

Quiz
•
KG - Professional Dev...
10 questions
Kuiz Kesedaran ISO

Quiz
•
University
10 questions
Quiz to unleash a ‘Revolutionary Approach to Market Entry and Ex

Quiz
•
University
12 questions
Global HRM

Quiz
•
University
7 questions
UNIT 5 part 1

Quiz
•
University
10 questions
20EI217 Industrial Automation Surprise Quiz 1

Quiz
•
University
10 questions
Desenho Técnico - NBR 16752 (escalas e papéis da série A)

Quiz
•
University
Popular Resources on Wayground
50 questions
Trivia 7/25

Quiz
•
12th Grade
11 questions
Standard Response Protocol

Quiz
•
6th - 8th Grade
11 questions
Negative Exponents

Quiz
•
7th - 8th Grade
12 questions
Exponent Expressions

Quiz
•
6th Grade
4 questions
Exit Ticket 7/29

Quiz
•
8th Grade
20 questions
Subject-Verb Agreement

Quiz
•
9th Grade
20 questions
One Step Equations All Operations

Quiz
•
6th - 7th Grade
18 questions
"A Quilt of a Country"

Quiz
•
9th Grade