In general with reference to AS3000, which of the following is an acceptable colour for active conductors? Table 3.4

Green

Yellow

Black

white

2.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Which of the mandatory tests detailed in AS3000 prevents electric shock hazards from inadvertent contact? 8.3.10

verification of RCD

correct circuit connections

fault-loop

impedance

insulation resistance

3.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Circuits supplying appliances with sheathed heating elements can have a minimum insulation resistance of not less than: 8.3.6.2(i)

1kΩ

10kΩ

0.2kΩ

10MΩ

4.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Which of the following circuits does NOT require RCD protection in a domestic installation?

socket outlets

lighting

circuits

directly connected hand held electrical equipment

Sub main

5.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Can a low voltage and extra low voltage wiring system be enclosed in a common enclosure? 3.9.8.3(c)

Yes, providing the cables are

installed in a separate compartment of a common cable trunking system

No

Yes, providing a distance of 300mm exists

Yes, providing the wiring system of the lower value consists of triple insulation

6.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

The termination of fixed wiring at a socket outlet or lamp holder is: 1.4.72

a point

point of entry

fixed wiring

open wiring

7.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Socket outlets must be connected so that: 4.4.5

the neutral and earth conductors may be connected together in the multiple earthed neutral system

when viewed from the front, the order of connection is Earth, Active and Neutral in a clockwise direction

when viewed from behind the order of connection is earth, Active and Neutral in a clockwise direction

the

Neutral and Earthed conductors are easily interchanged to suit requirements

of the local supply authority

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Microsoft

Continue with Microsoft

or continue with

Facebook

Facebook

Apple

Apple

Others

Others

Already have an account?