ICIT Revision D

ICIT Revision D

Professional Development

20 Qs

quiz-placeholder

Similar activities

INDUCTION MACHINES

INDUCTION MACHINES

Professional Development

19 Qs

pre-Quiz Day 2

pre-Quiz Day 2

Professional Development

15 Qs

Distribution

Distribution

Professional Development

15 Qs

FAC SERIES EXAMINATION

FAC SERIES EXAMINATION

1st Grade - Professional Development

19 Qs

Lesson 6: Power Generation and Distribution

Lesson 6: Power Generation and Distribution

University - Professional Development

24 Qs

F023 TAv07 - the lot

F023 TAv07 - the lot

Professional Development

16 Qs

Basic Electricity

Basic Electricity

Professional Development

20 Qs

Electronics by Sir AL

Electronics by Sir AL

Professional Development

15 Qs

ICIT Revision D

ICIT Revision D

Assessment

Quiz

Other

Professional Development

Hard

Created by

Y P Chai

Used 9+ times

FREE Resource

20 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which one of the following provisions is to enable proper functioning and control of current-using equipment for installation user?

Isolation

Functional switching.

Emergency switching.

Switching off for mechanical maintenance.

 

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The transformer used for distribution is 3-phase 4-wire system with star point connected to earth is

Delta-Delta Step-Down Transformer

Delta-Star Step-Down Transformer

Star-Star Step-Down Transformer

Star-Delta Step-Down Transformer

Answer explanation

the transformer used to step-down from 22kV to 400V, 50 Hz supply is Delta- Star connected transformer, the star point at secondary side (400V) is connected to earth.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In Singapore, the voltage between any two phases is 400V, 50 Hz and between any phase and the neutral is

230V, 50 Hz.

240V, 50 Hz.

230V, 60 Hz.

240V, 60 Hz.

Answer explanation

Our single-phase voltage is 230 V, 50 Hz.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Small non-domestic consumers, like flatted factories having industrial

loads are supplied with a 3-phase, 4-wire service cable to provide 230 V,

50 Hz single-phase and

400 V, 50 Hz three-phase.

415 V, 50 Hz three-phase.

400 V, 60 Hz three-phase.

415 V, 60 Hz three-phase.

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In order to balance the three phases system, consecutive services are connected to different phases and neutral in turn to

reducing the current in the neutral

so keeping the running costs up

increasing the current in the phase

increasing the current in the neutral

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The maximum electricity supply capacity for single-phase 230 V, 50 Hz provided by SP Services Ltd (SPSL) is

15 kVA

23 kVA

45 kVA

75 kVA

Answer explanation

Supply capacity at 230V, 50 Hz provided by SPSL is maximum 23 kVA or 100 A.

more than this will need 3-phase 400 V, 50Hz supply.

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

As in distribution system, it is important that the load currents are equally divided over the three phases to

improve the power factor

reduced the voltage drop on conductor.

.reduced the total power consumption.

balanced the current demand of the incoming supply.

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?