ICIT Revision D

ICIT Revision D

Professional Development

20 Qs

quiz-placeholder

Similar activities

H2 LW

H2 LW

Professional Development

16 Qs

Gk Marathon-11 Quiz

Gk Marathon-11 Quiz

10th Grade - Professional Development

15 Qs

Project Pursuit Assessment

Project Pursuit Assessment

Professional Development

15 Qs

Unit 1: Foundations of Psychology

Unit 1: Foundations of Psychology

University - Professional Development

20 Qs

GEN ANA 1 LAB ACTIVITY 2024

GEN ANA 1 LAB ACTIVITY 2024

University - Professional Development

20 Qs

High Impact Training - Ice Breaker 2

High Impact Training - Ice Breaker 2

Professional Development

20 Qs

Virtual Privilege Walk

Virtual Privilege Walk

Professional Development

15 Qs

NTDP - BUILDING PARTNERSHIP

NTDP - BUILDING PARTNERSHIP

Professional Development

15 Qs

ICIT Revision D

ICIT Revision D

Assessment

Quiz

Other

Professional Development

Hard

Created by

Y P Chai

Used 9+ times

FREE Resource

20 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which one of the following provisions is to enable proper functioning and control of current-using equipment for installation user?

Isolation

Functional switching.

Emergency switching.

Switching off for mechanical maintenance.

 

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The transformer used for distribution is 3-phase 4-wire system with star point connected to earth is

Delta-Delta Step-Down Transformer

Delta-Star Step-Down Transformer

Star-Star Step-Down Transformer

Star-Delta Step-Down Transformer

Answer explanation

the transformer used to step-down from 22kV to 400V, 50 Hz supply is Delta- Star connected transformer, the star point at secondary side (400V) is connected to earth.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In Singapore, the voltage between any two phases is 400V, 50 Hz and between any phase and the neutral is

230V, 50 Hz.

240V, 50 Hz.

230V, 60 Hz.

240V, 60 Hz.

Answer explanation

Our single-phase voltage is 230 V, 50 Hz.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Small non-domestic consumers, like flatted factories having industrial

loads are supplied with a 3-phase, 4-wire service cable to provide 230 V,

50 Hz single-phase and

400 V, 50 Hz three-phase.

415 V, 50 Hz three-phase.

400 V, 60 Hz three-phase.

415 V, 60 Hz three-phase.

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In order to balance the three phases system, consecutive services are connected to different phases and neutral in turn to

reducing the current in the neutral

so keeping the running costs up

increasing the current in the phase

increasing the current in the neutral

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The maximum electricity supply capacity for single-phase 230 V, 50 Hz provided by SP Services Ltd (SPSL) is

15 kVA

23 kVA

45 kVA

75 kVA

Answer explanation

Supply capacity at 230V, 50 Hz provided by SPSL is maximum 23 kVA or 100 A.

more than this will need 3-phase 400 V, 50Hz supply.

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

As in distribution system, it is important that the load currents are equally divided over the three phases to

improve the power factor

reduced the voltage drop on conductor.

.reduced the total power consumption.

balanced the current demand of the incoming supply.

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?