18th Edition Part 5 Mock 1

18th Edition Part 5 Mock 1

Professional Development

10 Qs

quiz-placeholder

Similar activities

ĐỐ VUI CÓ THƯỞNG B1_101

ĐỐ VUI CÓ THƯỞNG B1_101

Professional Development

12 Qs

SINH HOẠT CĐ

SINH HOẠT CĐ

1st Grade - Professional Development

15 Qs

Thu gom, phân loại, đổ rác thải sinh hoạt đúng quy định

Thu gom, phân loại, đổ rác thải sinh hoạt đúng quy định

Professional Development

15 Qs

Review Quiz

Review Quiz

Professional Development

10 Qs

INTERNAL AUDIT 1SO 19011:2018

INTERNAL AUDIT 1SO 19011:2018

Professional Development

10 Qs

LIQUID LIQUID EXTRACTION

LIQUID LIQUID EXTRACTION

University - Professional Development

15 Qs

LATIHAN 10 ( BM PEMAHAMAN ) PENGGANDAAN

LATIHAN 10 ( BM PEMAHAMAN ) PENGGANDAAN

Professional Development

15 Qs

Soal Extra - Quiz Webinar Harling 2022 KIDECO

Soal Extra - Quiz Webinar Harling 2022 KIDECO

University - Professional Development

15 Qs

18th Edition Part 5 Mock 1

18th Edition Part 5 Mock 1

Assessment

Quiz

Other

Professional Development

Practice Problem

Medium

Created by

Gareth Wyatt

Used 4+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Which one of the following devices would not be suitable for use as a circuit isolator?

a)        A device with semiconductors
b)        A contactor
c)         An RCD
d)        A fuse

2.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Wiring systems shall be selected and erected so as to be suitable for?

a)        The maximum ambient temperature
b)       The maximum conductor temperature
c)        The highest and lowest local ambient temperature
d)       The maximum and minimum conductor temperature

3.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Type 1 SPD's (Surge Protection Devices) are often referred to as?

a)         Exposed conductive SPD's
b)         Extraneous conductive SPD's
c)         Equipotential bonding SPD's
d)         Earth bonding SPD's

4.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

An item of switchgear is installed behind a fixed panel thus making the operation of the switchgear impossible for the operator to observe. In such situations a suitable indicator must be fixed in a position where the operator can see the effect of the operation, the indicator must comply with?

a)        BS EN 3535
b)        BS EN 4444 or BS EN 6346
c)        BS EN 60073 and BS EN 60447
d)        BS EN 12954

5.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

All outdoor lighting installations need to be carefully selected and erected, but which type of lighting is excluded from BS 7671?

a)       Festoon lighting that is temporary
b)        Road lighting
c)        Advertising signs
d)        Phone kiosks

6.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

What is the maximum operating temperature for thermosetting cables?

a)        70°c
b)        80°C
c)        90°C
d) 105°C

7.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

If the cross-sectional-area (c.s.a) of the supply PEN conductor where PME applies is 100 mm2, what is the minimum size the main protective bonding conductor can be?

a) 16 mm2
b)            25 mm2
c) 35 mm2
d) 50 mm2

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?