18th Edition Section 3

18th Edition Section 3

Professional Development

14 Qs

quiz-placeholder

Similar activities

Donning and Doffing PPE

Donning and Doffing PPE

Professional Development

10 Qs

Skill Area 9.0 - Mechanical Lifting Activities

Skill Area 9.0 - Mechanical Lifting Activities

Professional Development

10 Qs

Environmental Legislation (UK)

Environmental Legislation (UK)

Professional Development

12 Qs

18th Sept Health and Safety

18th Sept Health and Safety

Professional Development

18 Qs

health and safety

health and safety

Professional Development

14 Qs

Apprenticeship Study at the AMRC TC (Level 3)

Apprenticeship Study at the AMRC TC (Level 3)

Professional Development

13 Qs

MATERIAL HANDLING

MATERIAL HANDLING

University - Professional Development

10 Qs

BTS

BTS

KG - Professional Development

16 Qs

18th Edition Section 3

18th Edition Section 3

Assessment

Quiz

Education

Professional Development

Hard

Created by

Lee Williams

Used 8+ times

FREE Resource

14 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

28. The maximum temperature at the conductors of thermoplastic insulated cables is:      

90°C

70°C

105°C

60°C

2.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

29. What is the minimum level of IP protection provided by a trunking system for the protection of non-sheathed circuit cables?

IP2X

IP3X

IP4X

IP5X

3.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

 

30. A warning notice of maximum voltage present must be fixed to

  Where a nominal voltage of 230 V to earth exists where it would not normally be expected

400V between line conductors

230V single phase in a domestic property

Single-phase motors above 10 kW

4.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

31. A legible diagram, chart of table relating to an installation must be provided to indicate

The location of all fixed equipment for testing purposes

Any circuit of equipment vulnerable to a typical test

The location of all portable equipment for testing purposes

That the original installation design has not changed

5.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

32. A heater takes a design current of 32 A over a run of 15 metres using 4 mm2 two-core cable having a rated voltage drop of 11 mV/A/m. The total actual drop will be

9.6 V

6.0 V

5.28 V

2.5 V

6.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

33. What is the maximum preferable DC power supply system voltage for an auxiliary control circuit?

50 V

110 V

220 V

277 V

7.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

34. A cable joint must be accessible if it is

Designed to be buried in the ground

Made by welding, soldering or brazing

Compound-filled or encapsulated joint

Enclosed in a screw terminal junction box