1.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
Equipment is a general term used for material, fittings, devices, appliances, lighting fixtures, apparatus, machinery, and other parts used in connection with an electrical installation.
True
False
2.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
When installing service drop conductors above a residential roof, the general rule is that conductors must have a vertical clearance of at least __________.
10 feet
8 feet
3 feet
5 feet
3.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
Underground service conductors installed as a cable assembly are required to be buried at least __________ feet by the NEC.
3
1
2
4
4.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
When a warning ribbon is required to mark the location of buried underground service conductors, it must be placed at least __________ above the buried conductors.
12 inches
24 inches
18 inches
8 inches
5.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
When a metal underground water pipe is used as a grounding electrode, it must be in contact with the earth for at least __________ feet.
12
10
5
8
6.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
Ground rods must be at least __________ feet long.
10
8
12
6
7.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
According to NEC Table 250.66, the minimum size copper grounding electrode conductor for a service entrance installed with 4/0 copper conductors is __________.
2AWG
8AWG
6AWG
4AWG