UPC Review 11/3

UPC Review 11/3

Professional Development

72 Qs

quiz-placeholder

Similar activities

H&S Revision 2

H&S Revision 2

Professional Development

69 Qs

Model Code of Conduct

Model Code of Conduct

Professional Development

72 Qs

PI Roadmap revision

PI Roadmap revision

Professional Development

70 Qs

AIRLINES' CALLSIGNS 2

AIRLINES' CALLSIGNS 2

Professional Development

75 Qs

Piping

Piping

Professional Development

73 Qs

NPA Quiz 30.11.24

NPA Quiz 30.11.24

Professional Development

73 Qs

Audit - Revisions Basics

Audit - Revisions Basics

Professional Development

67 Qs

Cengage Accounting ll Final Exam Study Guide

Cengage Accounting ll Final Exam Study Guide

Professional Development

69 Qs

UPC Review 11/3

UPC Review 11/3

Assessment

Quiz

Professional Development

Professional Development

Easy

Created by

Gary Boyle

Used 30+ times

FREE Resource

72 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

The code requirement for “an adequate supply of potable running water” is for _____.

cleansing and sanitation

protection of trap seals

water-cooled equipment

hydronic systems

2.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Ballcocks in water closet tanks shall be installed so that the critical level of the water inlet is above the full opening of the overflow pipe at least _____.

1/2 inch

1 inch

3 inches

6 inches

3.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Minimum height of the atmospheric vacuum breaker critical level above all downstream piping for lawn sprinkler system: _____

1 inch

6 inches

12 inches

24 inches

4.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

After allowing for friction and other pressure losses, the residual water pressure shall be at least _____.

.433 psi

7.5 psi

15 psi

29 psi

5.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

The quantity of water required to be supplied to every plumbing fixture shall be represented by _____.

gallons per minute

feet per second

fixture units

available head pressure

6.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Solder and fluxes used in piping systems conveying potable water are prohibited when the lead content exceeds _____ percent.

0.2

0.5

1

1.5

7.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

The maximum trap loading for a 3 inch trap is _____.

one unit

three units

four units

six units