Pressure testing cold water pipework

Pressure testing cold water pipework

1st - 10th Grade

7 Qs

quiz-placeholder

Similar activities

08. Quality Management

08. Quality Management

1st - 3rd Grade

12 Qs

Formative Assessment

Formative Assessment

KG - 12th Grade

11 Qs

Note taking

Note taking

9th - 12th Grade

12 Qs

Health & Safety

Health & Safety

1st Grade

10 Qs

TOSCA ONBOARDING WEEK 1

TOSCA ONBOARDING WEEK 1

KG - Professional Development

12 Qs

PMI-ACP (10D)

PMI-ACP (10D)

1st Grade

10 Qs

Reading skills

Reading skills

7th Grade - University

10 Qs

Risk Response Strategies - Negative Risks

Risk Response Strategies - Negative Risks

4th Grade

6 Qs

Pressure testing cold water pipework

Pressure testing cold water pipework

Assessment

Quiz

Professional Development

1st - 10th Grade

Medium

Created by

Luke Rock

Used 5+ times

FREE Resource

7 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 3 pts

All water fittings should be capable of withstanding an internal water pressure of not less than................ times the maximum operating pressure.

1.2

1.5

1.7

2

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When testing rigid pipe systems all the outlets should be sealed and all float operated valves should be capped off or isolated.

The water pressure should then be increased, by pumping, until the lowest point in the installation is 50% above the normal operating pressure. This pressure should be maintained for..................... without further pumping.

30mins

1hour

1.5hours

2hours

3.

MULTIPLE SELECT QUESTION

45 sec • 1 pt

Which of the following problems should be rectified before testing?

Insufficient clips

Lagging pipes

incorrectly installed service valves

Make sure you have open ends

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Once a hydraulic test bucket has been used to pump up the pressure to the correct test pressure, how long should it be left for?

30mins

1hour

1.5hours

45mins

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

How many tests are there for systems containing plastic pipe?

1, test A

2, Test A and test B

3, Test A, B & C

1, same as the rigid pipe test

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Test A is passed if the pressure does not drop below one-third of the test pressure over the following............... minutes and there is no visible leakage throughout the test.

60mins

90mins

120mins

45mins

7.

MULTIPLE SELECT QUESTION

45 sec • 1 pt

The customer should be issued with which of the following documents during the handover:

The bill

Manufacturer's instructions

Warranty

Benchmark