1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following is the direct departure from BS7671 when a measured value of Ipf considerably exceeds those permitted for the protective devices installed at the point of test?

Earth fault disconnection times will be exceeded

Devices will safely interrupt the fault in time

Devices will not safely interrupt the fault in time

      Disconnection times will be exceeded

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the maximum permitted disconnection time for 100ma RCD to BSEN 61008 in order to meet specified time/current performance, when tested at 1xI n?

40ms

100ms

200ms

300ms

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which one of the following is used to establish phase sequencing for an installation

Frequency meter

Power factor indicator

Rotating disc instrument

Earth fault loop impedance tester

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which one of the following is the range tests that are carried out for RCD’s

½ x I△n  – 150 x I△n

½ x I△n –1 x I△n

½ x I△n  – 2 x I△n – 150 x I△n   

½ x I△n  – 2 x I△n – 5 x I△n 

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Functional tests are to be carried out on a general purpose RCD using a RCD tester. At which point during the testing process would the effectiveness of the test button on the RCD be checked.

Before the instrument test

Following all instrument tests

Following the 0.5 X I n test but before the 1 x I△n test

At no point as the instrument tests will carry out these functions

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The current measured between line and neutral at the origin of an electrical installation forming part of a TT system would be recorded as the

Design current

Nominal Current

Rated current

Prospective fault current

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The relationship between the maximum measured (Ipf) and the breaking capacity of any protective device is that the device breaking capacity is

Greater than the measured Ipf

Lower than the measured Ipf

Lower for ring circuits

Lower for radial circuits

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?