Design- Documentation

Design- Documentation

5th Grade

6 Qs

quiz-placeholder

Similar activities

MGT420 - CHAPTER 8

MGT420 - CHAPTER 8

1st - 3rd Grade

10 Qs

Periodic Table isn't difficult

Periodic Table isn't difficult

1st - 3rd Grade

10 Qs

QUIZ CHAP.2 (2)

QUIZ CHAP.2 (2)

1st - 5th Grade

10 Qs

Quiz chap 1(c)

Quiz chap 1(c)

1st - 3rd Grade

10 Qs

COT SCI 3

COT SCI 3

1st - 5th Grade

5 Qs

Fire Alarm and Detection System

Fire Alarm and Detection System

1st - 3rd Grade

5 Qs

All About Transformers

All About Transformers

1st Grade

10 Qs

Q1 / Block B Roof NZ/Building Control Framework

Q1 / Block B Roof NZ/Building Control Framework

1st Grade

10 Qs

Design- Documentation

Design- Documentation

Assessment

Quiz

Education

5th Grade

Medium

Created by

Adam Kerrigan

Used 2+ times

FREE Resource

6 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Specific guidance is given to the selection of cables, isolation, switching, and inspection and testing for electrical installations in the:

IET Wiring Regulations

Electricity Supply Regulations

Electricity at Work Regulations

Health and Safety at Work Act

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Exploded views in manufacturers’ manuals are generally used to show

Large machine parts

Machines having few parts

Wiring diagrams of machines and systems

Complex components having many parts

Answer explanation

Media Image

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

An electrical contractor, compiling a list of materials and equipment required to complete an installation, will need access to

Delivery records

Drawings and specifications

Circuit diagram

Day work sheets and variations

Answer explanation

Media Image

Installation drawings are usually to scale meaning position of equipment/accessories can be transferred from the drawing to the correct position. 1:50, 1:100, 1:150 etc are common scales that are used.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Circuits that are used to measure and control temperature, air flow and humidity in a building are called

Emergency management circuits

Environmental control circuits

Power control circuits

Security con

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A line on a drawing measuring 200mm, representing a wall on a site measuring 200m will be drawn to a scale of

1:500

1:1,000

1,000:1

500:1

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When deciding the maximum fixing distances for conduit saddles, reference should be made to

BS 7671 

On-Site Guide 

Guidance notes 3 

The Electricity at Work Regulations

Answer explanation

Media Image

The IET Wiring Regulations 18th Edition-Amendment 2 is the comprehensive, detailed guide to electrical installation, design and maintenance in the UK. It contains multiple updates from the 17th Edition which are intended to make electrical installations more effective, safer and more efficient.