2018 IFGC CH 5B

2018 IFGC CH 5B

Professional Development

25 Qs

quiz-placeholder

Similar activities

Day 2 RECAP of SHAKE-SMILER + Virtual Workshop

Day 2 RECAP of SHAKE-SMILER + Virtual Workshop

Professional Development

20 Qs

Schizophrenia

Schizophrenia

Professional Development

20 Qs

Proposotions temporelles

Proposotions temporelles

Professional Development

20 Qs

HR Policies and Procedures

HR Policies and Procedures

Professional Development

20 Qs

Preelaboraciónes en la cocina

Preelaboraciónes en la cocina

1st Grade - Professional Development

20 Qs

Batch 2 Post Test 1 Analyzing Data Using Ms. Excel

Batch 2 Post Test 1 Analyzing Data Using Ms. Excel

Professional Development

20 Qs

TEMA 7. LAS PRUEBAS (CONFESION JUDICIAL)

TEMA 7. LAS PRUEBAS (CONFESION JUDICIAL)

Professional Development

20 Qs

Round 01

Round 01

5th Grade - Professional Development

20 Qs

2018 IFGC CH 5B

2018 IFGC CH 5B

Assessment

Quiz

Other

Professional Development

Medium

Created by

Johnny Thulin

Used 4+ times

FREE Resource

25 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

·         01.Gas vents shall be supported in accordance with ________________.
1.  a.the manufacturer’s instructions
2.  b.the referenced standard
3.  c.the accepted engineering practice
4.  d.the label on the vent

2.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

·         02.A single-wall metal pipe vent shall terminate at least ______________inches higher than any portion of a building within 10 feet horizontally.
1.  a.24
2.  b.30
3.  c.36
4.  d.42

3.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

·         03.Where double-wall vents are installed, fasteners shall ______________.
1.  a.be spaced evenly around the vent
2.  b.not penetrate the inner wall.
3.  c.not be used at the transition from a flue collar
4.  d.be aluminum or stainless steel

4.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

·         04.Single-wall metal pipe vent shall be constructed of galvanized sheet steel not less than ______________ in thickness.
1.  a.0.0360 inch
2.  b.0.0304 inch
3.  c.0.0240 inch
4.  d.0.0190 inch

5.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

·         05.For single-wall metal pipe to be used outdoors for venting appliances, the 99-percent winter design temperature must not be less than __________________ degrees Fahrenheit.
1.  a.0
2.  b.32
3.  c.40
4.  d.50

6.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

·         06.A single-wall metal pipe vent shall terminate at least _______________ feet in vertical height above the highest appliance draft hood outlet.
1.  a.5
2.  b.10
3.  c.15
4.  d.20

7.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

·         07.When terminating above a roof, a single-wall metal pipe vent shall extend at least __________________ above the highest point where it passes through the roof.
1.  a.1 foot
2.  b.2 feet
3.  c.3 feet
4.  d.4 feet

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?