1.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
01. A __________ is required to discharge indirectly through an air gap to the sanitary drainage system.
1. a. food-preparation sink
1. b. pots-and-pans sink
1. c. domestic dishwashing machine
1. d. commercial dishwashing machine
2.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
02. A __________ is allowed to discharge through an air break into an indirect waste receptor.
2. a. swimming pool deck drain
2. b. food-preparation sink
2. c. commercial dishwashing machine
2. d. sterilizer
3.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
03. Floor drains in walk-in refrigerators of food establishments shall be __________.
3. a. directly connected to the drainage system
directly connected to the drainage system protected with a backwater valve
indirectly connected to the drainage system by means of an air gap
indirectly connected to the drainage system by means of an air break
4.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
04. Fixtures that discharge through an indirect waste connection are required to be trapped when the fixture drain exceeds __________ inches in horizontal developed length.
4. a. 36
4. b. 72
4. c. 30
4. d. 48
5.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
05. An indirect waste receptor must be sized based on the ____________ of the fixtures served.
5. a. largest indirect waste pipe b. maximum discharge
5. b. maximum discharge
5. c. fixture units
5. d. function
6.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
06. A hub drain receiving the discharge from an ice storage bin through an air gap and connected to the sanitary drainage system is not required to __________.
6. a. be trapped and vented
6. be equipped with a removable strainer
6. c. be designed and installed to prevent splashing
6. d. extend a minimum of 1 inch above the surrounding floor
7.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
07. Corrosive liquids that may harm drainage piping are prohibited from being discharged to the sanitary drainage system unless first __________.
7. a. permitted for discharge by state and federal agencies
7. filtered through a diatomaceous earth filtration system
7. c. diluted by water or passed through a neutralizing medium
tested to determine that they are not corrosive to the piping system
Access all questions and much more by creating a free account