Random Fuel Gas

Random Fuel Gas

Professional Development

40 Qs

quiz-placeholder

Similar activities

Steering and tire system

Steering and tire system

Professional Development

40 Qs

Treasure Hunt

Treasure Hunt

Professional Development

35 Qs

Quiz-6 May

Quiz-6 May

Professional Development

35 Qs

Eastern Pennsylvania FFA Vet Tech CDE Question Bank 160-200

Eastern Pennsylvania FFA Vet Tech CDE Question Bank 160-200

Professional Development

41 Qs

Sales  Quiz

Sales Quiz

Professional Development

42 Qs

Chapter 7 - Trichology Pt 1

Chapter 7 - Trichology Pt 1

Professional Development

40 Qs

Central heating trail 4

Central heating trail 4

Professional Development

42 Qs

Pre Test_HR Practices For Foreman

Pre Test_HR Practices For Foreman

Professional Development

35 Qs

Random Fuel Gas

Random Fuel Gas

Assessment

Quiz

Other

Professional Development

Easy

Created by

Johnny Thulin

Used 5+ times

FREE Resource

40 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

·         06.Appliance connections to a chimney or vent equipped with a power exhauster shall be made on the ______________ side of the exhauster.
1.  a.outlet
2.  b.inlet
3.  c.positive
4.  d.discharge
Reference Section(s): 501.10

2.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

·         03.Unless incorporated as part of the appliance, a sediment trap shall be installed ___________.
1.  a.downstream of the appliance shutoff valve
2.  b.remote from the appliance location
3.  c.upstream of the appliance shutoff valve
4.  d.upstream of the manifold
Reference Section(s): 408.4

3.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

25.Within dwelling units, unobstructed _____________ are permitted to convey combustion air.
97. a.shafts
98. b.stud and joist spaces
99. c.chases enclosing chimneys
100.           d.chimneys
Reference Section(s): 304.11, Item 1 Exception

4.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

·         09.Field drilled and tapped pipe fittings are permitted under limited conditions when the work is performed by ___________________.
1. a.a licensed pipefitter
2. b.the contractor holding the permit
3. c.an approved third-party agency
4. d.the gas supplier
Reference Section(s): 403.10.5, Item 9.2

5.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

·    02.Appliances having an ignition sources shall be elevated such that the ignition source is not less than ________________ inches above the floor in a private garage.
1.      a.12
2.      b.18
3.      c.6
4.      d.30
Reference Section(s): 305.3

6.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

9.    09.Hangers for a suspended unit heater must be _________.
1. a.designed by a registered design professional
2. b.steel angle iron
3. c.provided by the appliance manufacturer
4. d.noncombustible
Reference Section(s): 620.2

7.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

10. 10.Suspended type unit heaters shall be installed with clearances to combustible materials of not less than _______________ inches at the sides of the unit.
1. a.6
2. b.12
3. c.18
4. d.24
Reference Section(s): 620.4

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?