Philippine Electrical Code (Subject 4) - Nth

Philippine Electrical Code (Subject 4) - Nth

University

50 Qs

quiz-placeholder

Similar activities

RAD 156 Exam 1 Review

RAD 156 Exam 1 Review

University

45 Qs

OPEN BOOK EXAM 6

OPEN BOOK EXAM 6

University - Professional Development

50 Qs

PEC 2

PEC 2

University

50 Qs

OPENBOOK EXAM #3

OPENBOOK EXAM #3

University

48 Qs

GEAS 21

GEAS 21

University

50 Qs

FOR PREPARTION

FOR PREPARTION

University

45 Qs

My RME Reviewer

My RME Reviewer

University

50 Qs

PART 4: MCQ from Number 151 – 200

PART 4: MCQ from Number 151 – 200

University

50 Qs

Philippine Electrical Code (Subject 4) - Nth

Philippine Electrical Code (Subject 4) - Nth

Assessment

Quiz

Other

University

Medium

Created by

Norlan Hiponia

Used 32+ times

FREE Resource

50 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

1. The overhead conductors, through which electrical service is supplied, between the last power company pole and the building or other support used for the purpose are called:

Service entrance

Service-entrance conductors

Service drop

Service-entrance equipment

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

2. The conductors and equipment for delivering electric energy from the power company to the wiring system of the premises served is called a:

Service

Service-entrance conductors

Service drop

Service-entrance equipment

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

3. The conductors between the point of termination of the overhead service drop or underground service lateral and the main disconnecting device in a building are known as:

Service

Service conductors

Service drop

Service-entrance equipment

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

4. The necessary equipment connected to the load end of the service conductors to a building or other structure and intended to constitute the main control and cutoff of the supply is known as:

Service entrance

Service-entrance conductors

Service drop

Service equipment

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

5. The underground conductors through which service is supplied between the power company’s distribution facilities and the first point of their connection to a building or area service facilities located at the building or other support used for the purpose are known as:

Service clearance

Service lateral

Parallel connection

Weatherhead

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

6. In a balanced three-phase, 4-wire system, the current in the neutral conductor:

Is the same as in the other conductors

Is lower than in the other conductors

Is higher than in the other conductors

Will not flow when all loads are exactly balanced

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

7. On a 240-volt, single-phase, 3-wire system, the neutral conductor will:

Never carry current even if the other conductors carry current

Never carry current larger than the difference between the current in the two ungrounded (“hot”) conductors

Carry current equal to the current between phases

Carry current equal to one-half the current between phases

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?