MASTER OPENBOOK EXAM #5

MASTER OPENBOOK EXAM #5

University

70 Qs

quiz-placeholder

Similar activities

PENGANTAR PROMOSI KESEHATAN

PENGANTAR PROMOSI KESEHATAN

University

70 Qs

Ukom gizi okt 2023 - 1

Ukom gizi okt 2023 - 1

University

70 Qs

CnI_Komunikasi Digital

CnI_Komunikasi Digital

University

65 Qs

Kisi-Kisi_Rangkaian Listrik (UAS)

Kisi-Kisi_Rangkaian Listrik (UAS)

University

65 Qs

Nutrition- Midterm

Nutrition- Midterm

University

67 Qs

Latihan Penguasaan Materi PSAJ Bahasa Jepang

Latihan Penguasaan Materi PSAJ Bahasa Jepang

12th Grade - University

65 Qs

ôn tập kiểm tra giữa kỳ K12_2024-2025

ôn tập kiểm tra giữa kỳ K12_2024-2025

12th Grade - University

65 Qs

cia 5 science review

cia 5 science review

5th Grade - University

75 Qs

MASTER OPENBOOK EXAM #5

MASTER OPENBOOK EXAM #5

Assessment

Quiz

Other

University

Practice Problem

Medium

Created by

Road RME

Used 3+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

70 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The minimum size conductor permitted in parallel for elevator lighting is ___, provided the ampacity is equivalent to a #14 wire.

#14

#20

#16

#1/0

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Conductors of light and power systems of all voltages may occupy the same enclosure or raceway ___.

if less than 600 volts and if insulated for maximum voltage of any conductor within the enclosure or raceway

if power system is over 600 volts and light system under 600 volts

if power system is over 600 volts and individual circuits are AC

in most instances without qualification

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Transformers rated over ___ KV shall be in a vault.

10

12 1/2

25

35

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The neutral of feeders supplying solid-state, 3-phase, 4-wire dimming systems shall be considered a ___ conductor.

current-carrying

noncurrent-carrying

balanced

isolated

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Tubing having cut threads and used as arms or stems on light fixtures may not be less than ___ inches wall thickness.

.020

.025

.040

.015

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Expansion fitting for nonmetallic wireway shall be provided to compensate for thermal expansion and contraction where the length change is expected to be ___ or greater in a straight run.

.025 in

.25 mm

6.36 in

6.36 mm

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Types TPT, TS and TST shall be permitted in lengths not exceeding ___ feet when attached directly, or by means of a special type of plug, to a portable appliances rated at 50 watts or less.

8

10

15

can’t be used at all

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?