1.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
In damp or wet locations, cabinets and cutout boxes of the surface type shall be mounted so there is at least ___ air space between the enclosure and the wall or other supporting surface.
6.35”
6”
3/4”
1/4”
2.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
An 86 cubic inch junction box has two 1/2” rigid metal conduits entering the box. The conduits are supported within 36” of the box. The conduits enter the box through threaded hubs, one conduit through the top of the box. Select the correct statement concerning the Code requirements for this type of installation.
The conduits must be supported within 18” of the box.
The conduits must be supported within 12” of the box.
The Code requires this box to be supported.
The Code does not require this box to be supported.
3.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
The disconnecting means shall be ___ of the sign or outline lighting that it controls.
I. within sight of sign II. within 50’ of sign III. within 75’ of sign
I only
II only
I and II only
I and III only
4.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
The thermoplastic insulation for fixture wires may be deformed at ___ temperature where subjected to pressure, requiring care to be exercised during installation and at points of support.
I. 0 degrees F II. 72 degrees F III. 212 degrees F
I only
II only
III only
II and III only
5.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
The installation of underfloor raceways shall be permitted.
I. beneath the surface of concrete
II. beneath floor material other than concrete
III. where laid flush with the concrete floor and covered with linoleum
I only
II only
III only
I, II and III
6.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
FCC carpet squares that are adhered to the floor shall be attached with ___.
tacking strip
release-type adhesive
glue
none of these
7.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
Electric equipment with a metal enclosure or with a nonmetallic enclosure listed for the used and having adequate ___ producing characteristics. And associated wiring material suitable for the ambient temperature shall be permitted to be installed in other space used for environmental air unless prohibited in this Code.
I. fire-resistant II. low-smoke
I or II
I and II
I only
II only
Create a free account and access millions of resources
Similar Resources on Wayground
67 questions
BF LESSON 1&2

Quiz
•
University
70 questions
MASTER OPENBOOK EXAM #4

Quiz
•
University
68 questions
MAS 3301

Quiz
•
University
70 questions
Coach Lawry Part 2

Quiz
•
1st Grade - University
65 questions
MPJE Section 1 Q's 16-20

Quiz
•
University
70 questions
HEMATOLOGY - WEEK 2 RATIONALE

Quiz
•
University
75 questions
cm4 exam

Quiz
•
University
65 questions
Astro 115 Ch10

Quiz
•
University
Popular Resources on Wayground
50 questions
Trivia 7/25

Quiz
•
12th Grade
11 questions
Standard Response Protocol

Quiz
•
6th - 8th Grade
11 questions
Negative Exponents

Quiz
•
7th - 8th Grade
12 questions
Exponent Expressions

Quiz
•
6th Grade
4 questions
Exit Ticket 7/29

Quiz
•
8th Grade
20 questions
Subject-Verb Agreement

Quiz
•
9th Grade
20 questions
One Step Equations All Operations

Quiz
•
6th - 7th Grade
18 questions
"A Quilt of a Country"

Quiz
•
9th Grade