MASTER OPENBOOK EXAM #8

MASTER OPENBOOK EXAM #8

University

70 Qs

quiz-placeholder

Similar activities

KMC Quiz

KMC Quiz

12th Grade - Professional Development

65 Qs

SAR Trivia

SAR Trivia

KG - University

68 Qs

UNIT 1

UNIT 1

University

65 Qs

EXAMEN 1 - Cap1 -3 + Gestion Legal

EXAMEN 1 - Cap1 -3 + Gestion Legal

University

70 Qs

QTRM

QTRM

University

66 Qs

Rad Path Chapter 5 GI System

Rad Path Chapter 5 GI System

University

70 Qs

SOAL UTS KMB.II ( SMT 4 ) DOSEN : ROSA DELIMA & TIM

SOAL UTS KMB.II ( SMT 4 ) DOSEN : ROSA DELIMA & TIM

University

70 Qs

QUIZ - SKD CPNS 2021

QUIZ - SKD CPNS 2021

University

74 Qs

MASTER OPENBOOK EXAM #8

MASTER OPENBOOK EXAM #8

Assessment

Quiz

Other

University

Practice Problem

Hard

Created by

Road RME

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

70 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In damp or wet locations, cabinets and cutout boxes of the surface type shall be mounted so there is at least ___ air space between the enclosure and the wall or other supporting surface.

6.35”

6”

3/4”

1/4”

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

An 86 cubic inch junction box has two 1/2” rigid metal conduits entering the box. The conduits are supported within 36” of the box. The conduits enter the box through threaded hubs, one conduit through the top of the box. Select the correct statement concerning the Code requirements for this type of installation.

The conduits must be supported within 18” of the box.

The conduits must be supported within 12” of the box.

The Code requires this box to be supported.

The Code does not require this box to be supported.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The disconnecting means shall be ___ of the sign or outline lighting that it controls.

 

I. within sight of sign                      II.  within 50’ of sign                       III. within 75’ of sign

I only

II only

I and II only

I and III only

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The thermoplastic insulation for fixture wires may be deformed at ___ temperature where subjected to pressure, requiring care to be exercised during installation and at points of support.

I. 0 degrees F                    II. 72 degrees F                 III. 212 degrees F

I only

II only

III only

II and III only

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The installation of underfloor raceways shall be permitted.

 

I.       beneath the surface of concrete

II.     beneath floor material other than concrete

III.    where laid flush with the concrete floor and covered with linoleum

I only

II only

III only

I, II and III

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

FCC carpet squares that are adhered to the floor shall be attached with ___.

tacking strip

release-type adhesive

glue

none of these

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Electric equipment with a metal enclosure or with a nonmetallic enclosure listed for the used and having adequate ___ producing characteristics. And associated wiring material suitable for the ambient temperature shall be permitted to be installed in other space used for environmental air unless prohibited in this Code.

I. fire-resistant                  II. low-smoke

I or II

I and II

I only

II only

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?