1.

MULTIPLE CHOICE QUESTION

1 min โ€ข 1 pt

it shall be unlawful for any person to cause, suffer or permit the disposal of sewage, human excrement or other waste waters in any place or manner, except through and by means of an approved______ installed and maintained

Excreta and Storm Drainage Systems

storm drainage only

2.

MULTIPLE CHOICE QUESTION

1 min โ€ข 1 pt

Horizontal drainage pipes shall be run in practical alignments and at a uniform slope between manholes of not less than _____ toward the point of disposal

20 mm/m or 2%

10 mm/m or 1%

3.

MULTIPLE CHOICE QUESTION

1 min โ€ข 1 pt

such pipe or piping 102 mm or larger in diameter may have a slope of ____ provided it is first approved by the Administrative Authority.

10 mm/m or 1%

20 mm/m or 2%

4.

MULTIPLE CHOICE QUESTION

1 min โ€ข 1 pt

Changes in direction of drainage piping shall be made by the use of approved pipe fittings and shall be of the angles presented by a 22 l/2ยฐ bend, 45ยฐ bend, 60ยฐ bend or other approved fittings of ____

longer sweeps

shorter sweeps.

5.

MULTIPLE CHOICE QUESTION

1 min โ€ข 1 pt

Horizontal drainage lines connecting to a vertical stack shall enter through ____, combination wye and 1/8 bend branches, sanitary tee or other approved fittings of longer sweeps

45ยฐ or 60ยฐ wye branches

45ยฐ or 90ยฐ wye branches

6.

MULTIPLE CHOICE QUESTION

1 min โ€ข 1 pt

No fitting having more than one inlet at the ____shall be used unless such fitting is constructed so that the discharge from one inlet cannot readily enter into the other inlet.

same level

below level

7.

MULTIPLE CHOICE QUESTION

1 min โ€ข 1 pt

Vertical installation of _____ may be used when the barrel of the fitting is at least two (2) pipe sizes larger than the largest side inlet.

double sanitary tees

double sanitary wye

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?