fire/fuel2

fire/fuel2

University

10 Qs

quiz-placeholder

Similar activities

RAPAT TELECONFERENCE

RAPAT TELECONFERENCE

12th Grade - University

10 Qs

Food Safety

Food Safety

University - Professional Development

10 Qs

KUIS 5,6,7 PEMASARAN FARMASI

KUIS 5,6,7 PEMASARAN FARMASI

University

10 Qs

Purification & Types of water

Purification & Types of water

1st Grade - Professional Development

15 Qs

The U.S. Government

The U.S. Government

University

12 Qs

T6_Global Issues

T6_Global Issues

1st Grade - Professional Development

14 Qs

bts army

bts army

KG - Professional Development

10 Qs

rubiks cube quiz

rubiks cube quiz

KG - Professional Development

13 Qs

fire/fuel2

fire/fuel2

Assessment

Quiz

Other

University

Practice Problem

Medium

Created by

Timothy Robinson

Used 35+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

Using the accompanying servicing chart, which of the following pairs of readings indicates a properly charged fire-extinguishing bottle?

-30 F and 450 psig.

40 F and 400 psig.

40º F and 475 psig.

0 F and 300 psig.

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Should a Class A/B/C fire extinguisher be used on ALL types of fires?

Yes

No

Depends if indoors or outdoors

Only if no alternate is availableOnly if no alternate is available

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In a HRD fire extinguishing systems, there are 2 blowout discs. What are their purposes?

There is no difference. The colours are at the manufactures option

The Red Disc indicates a normal use of the extinguishing system, the yellow indicates a thermal blowout

A missing yellow disc indicates a normal use of the extinguishing system, a missing red indicates a thermal blowout

The Yellow disc indicates normal system charge, the red disc indicates a system overcharge.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Light refraction smoke detectors are activated when the detector

measures a reduction in the amount of visible or infrared light in the surrounding area.

senses light reflected from smoke particles passing through a chamber.

uses radiation induced ionization to detect the presence of smoke.

Senses smoke from flammable sources at temperatures above 100⁰C

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When used in fire-detection systems having a single indicator light, thermal switches are wired in:

parallel with each other and in series with the light.

series with each other and parallel with the light.

Parallel/series hybrid control circuits with repeaters

series with each other and the light.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In a Fenwal fire detection System, what would happen if the wire is pinched or kinked crushing the casing and centre wires together?

The system would cause a false indication immediately

The system would fail to function

There would be no effect on the system and it would function normally as there are two wires inside the casing to prevent this from happening

The system would work properly for the section of the detector between the damaged area and the connector.

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A fuel temperature indicator is located in the fuel tanks on some turbine powered airplanes to tell when the fuel is

getting cold enough to form hard ice.

in danger of forming ice crystals

about to form rime ice

at it’s best potential for making horsepower. This information is used in charts found in the Pilot Operating Handbook

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?