Philippine Electrical Code (Subject 5) - Nth

Philippine Electrical Code (Subject 5) - Nth

University

50 Qs

quiz-placeholder

Similar activities

EST 33

EST 33

University

50 Qs

OPEN BOOK EXAM 9

OPEN BOOK EXAM 9

University

50 Qs

NBA

NBA

KG - Professional Development

47 Qs

Philippine Electrical Code (Subject 1) - Nth

Philippine Electrical Code (Subject 1) - Nth

University

50 Qs

Facial Bones and Orbits Quiz

Facial Bones and Orbits Quiz

University

50 Qs

Philippine Electrical Code (Subject 4) - Nth

Philippine Electrical Code (Subject 4) - Nth

University

50 Qs

Philippine Electrical Code (Subject 3) - Nth

Philippine Electrical Code (Subject 3) - Nth

University

50 Qs

Philippine Electrical Code (Subject 2) - Nth

Philippine Electrical Code (Subject 2) - Nth

University

50 Qs

Philippine Electrical Code (Subject 5) - Nth

Philippine Electrical Code (Subject 5) - Nth

Assessment

Quiz

Other

University

Medium

Created by

Norlan Hiponia

Used 25+ times

FREE Resource

50 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

1. All metal enclosures for service conductors and equipment must be:

Grounded

Ungrounded

Made from 10 gauge steel or above

PVC (plastic)

2.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

2. On a switchboard with busbars, phase B would have the highest voltage to ground in a:

Delta-Wye system

High-leg delta-connected system

Wye-Wye system

Scott connection

3.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

3. A 200-ampere panelboard may supply a maximum load of:

100 amperes

180 amperes

160 amperes

200 amperes

4.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

4. Which of the following is not a requirement for an intersystem bonding termination?

Consists of at least three terminals

Contains at least 50 percent bronze or brass

It be accessible for connection and inspection

It be listed for grounding and bonding

5.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

5. Branch circuit conductors supplying information technology equipment shall have an ampacity of:

20 amperes maximum

25 amperes minimum

250 percent of the computed load

125 percent of the connected load

6.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

6. What is the maximum number of overcurrent devices permitted in a panelboard?

40

No fewer than the maximum busbar rating after all correction factors have been applied

As many as will fit

More than 42 requires that a permanent label be affixed to the deadfront

7.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

7. Insulated grounded conductors, in sizes larger than No. 6 AWG, may be identified by:

Continuous white or natural gray outer finish

Three continuous white stripes on other than green insulation

Distinctive white markings encircling the conductor at its terminations

All of the above