HVAC FC 04

HVAC FC 04

Professional Development

70 Qs

quiz-placeholder

Similar activities

ADX 201 Quiz 1

ADX 201 Quiz 1

Professional Development

65 Qs

Mcdonals

Mcdonals

Professional Development

74 Qs

HVAC FC 01

HVAC FC 01

Professional Development

69 Qs

CHP 1 Comprehensive Medical Assisting Study Guide

CHP 1 Comprehensive Medical Assisting Study Guide

Professional Development

70 Qs

Penyaman Udara Aircond HVAC

Penyaman Udara Aircond HVAC

12th Grade - Professional Development

70 Qs

Tatabahasa Latihan 2

Tatabahasa Latihan 2

1st Grade - Professional Development

70 Qs

CHP 7 Comprehensive Medical Assisting Study Guide

CHP 7 Comprehensive Medical Assisting Study Guide

Professional Development

74 Qs

ADX 201 Quiz 3

ADX 201 Quiz 3

Professional Development

65 Qs

HVAC FC 04

HVAC FC 04

Assessment

Quiz

Other

Professional Development

Medium

Created by

Johnny Thulin

Used 2+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

70 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The ___ is the temperature below which water vapor in the air will start to condensate.
wet bulb point
dry bulb point
dew point
sensible point

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Why is it necessary to be cautios when handling contaminanted refrigerant oil?
It may contain PCBs
It may be acid
It is highly Flammable
It is known carcinogen

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When pressure testing hydronic systems, the pressure shall be maintained for a MINIMUM of
15 minutes
30 minutes
45 minutes
1 hour

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The ____ measures the rate of flow of current.
volt
ampere
power
watt

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which types of gauges are used to check pressures on an absorption system?
steel manifold gauges
brass manifold gauges
copper manifold gauges
aluminum manifold gauges

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A crankcase heater installed in a Heat Pump System is being used to _____.
protect the compressor from "freeze-up"
provide supplemental heat
prevent liquid refrigerant build-up in the compressor
produce supplemental vapor

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Previous step to connecting a regulator to a fuel-gas cylinder valve is:
to crack the seal with a metal rod
to open the valve quickly until a cracking sound is heard
to tap the regulator with a wrench to loosen any dust or dirt on it
to open the valve slightly and close it immediately

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?