Construction II

Construction II

University

10 Qs

quiz-placeholder

Similar activities

SFD and BMD

SFD and BMD

University

15 Qs

RES- SOLAR CONSTANT, RADIATIONS

RES- SOLAR CONSTANT, RADIATIONS

University

10 Qs

ME1 Unit 1B Shiphandling in Seaspeak

ME1 Unit 1B Shiphandling in Seaspeak

University

6 Qs

ECM346_Week 10 Building Transportation

ECM346_Week 10 Building Transportation

University

10 Qs

Chapter 1 Introduction to Accounting ACC117 Uitm

Chapter 1 Introduction to Accounting ACC117 Uitm

University

10 Qs

CHAPTER 3: ACCOUNTING CYCLE

CHAPTER 3: ACCOUNTING CYCLE

University

10 Qs

ECD 132 Chapter 3 Practice Quiz

ECD 132 Chapter 3 Practice Quiz

University

10 Qs

Quiz Briefing of Outcome-based Education (OBE) OCT 2020

Quiz Briefing of Outcome-based Education (OBE) OCT 2020

University

13 Qs

Construction II

Construction II

Assessment

Quiz

Education

University

Hard

Created by

Chieng Koh

Used 3+ times

FREE Resource

10 questions

Show all answers

1.

MULTIPLE SELECT QUESTION

5 mins • 1 pt

The following statements are associated with the ground floor of a double-storey semi-detached house building. Please select ALL the TRUE statements.

In total, there are four (4) different beam sizes on the ground floor.

In total, there are eight (8) different column sizes on the ground floor.

The ground slab thickness is 115mm

The finish level (FL) at W.C = 5.45m

2.

MULTIPLE SELECT QUESTION

5 mins • 1 pt

The following statements are associated with the pilecap and column stump of a double-storey semi-detached house building. Please select ALL the TRUE statements.

The smallest size of column stump is 150 x 230, whereas the biggest is 400 x 400.

The total number of column mark C1 is 12.

The details of two piles pilecap between P2 and P2A is exactly the same.

The details of one pile pilecap between P1 and P1A is not the same.

3.

MULTIPLE SELECT QUESTION

5 mins • 1 pt

The following statements are associated with the reinforced concrete of a double-storey semi-detached house building. Please select ALL the TRUE statements.

Concrete for floor beam and slab shall be Grade 20.

Concrete cover to pilecap shall be 50mm.

Concrete for pilecap shall be Grade 20

"Y" denoted as high steel deformed bar whereas, "R" denoted as mild steel round bar.

4.

MULTIPLE SELECT QUESTION

5 mins • 1 pt

The following statements are associated with the first floor (inclusive of car porch beam) of a double-storey semi-detached house building. Please select ALL the TRUE statements.

In total, there are five (5) different beam sizes on the first floor.

In total, there are five (5) different column sizes on the first floor.

The height difference between the car porch beam and the first floor beam is 850mm

The finish level (FL) at balcony = 8.825m

5.

MULTIPLE SELECT QUESTION

5 mins • 1 pt

The following statements are associated with the roof beam of a double-storey semi-detached house building. Please select ALL the TRUE statements.

There are two (2) different beam sizes on the roof level.

There are three (3) sizes of the mild steel round bar for the roof beam

There are two (2) sizes of the high tensile deform bottom bar for the roof beam

There are three (3) sizes of the high tensile deform top bar for the roof beam

6.

MULTIPLE SELECT QUESTION

5 mins • 1 pt

The following statements are associated with the staircase of a double-storey semi-detached house building. Please select ALL the TRUE statements.

There are two (2) sizes of mild steel round bar being used for the staircase construction

There are two (2) intervals of steel spacing being used for the staircase construction

There are four (4) sizes of high yield deformed bar being used for the staircase construction

The staircase consists of nineteen (19) steps from the ground floor to the first floor

7.

MULTIPLE SELECT QUESTION

5 mins • 1 pt

The following statements are associated with the roof construction of a double-storey semi-detached house building. Please select ALL the TRUE statements.

A 22-degree and 18-degree pitch are employed for all the concrete tile roofing.

The spacing of the roof battens is about 350mm on a single layer of aluminum sisalation paper.

The fascia board is not being used for the roofing.

A 175mm wide galvanized iron Colorbond gutter is being used for the roofing.