РО 4.5

РО 4.5

University

22 Qs

quiz-placeholder

Similar activities

Are You Smarter Than A Trailblazer?

Are You Smarter Than A Trailblazer?

University

20 Qs

Conocimientos generales

Conocimientos generales

12th Grade - University

20 Qs

Kiểm tra 15p - môn Toán 12C1

Kiểm tra 15p - môn Toán 12C1

11th Grade - University

20 Qs

HIPAA Privacy Rules

HIPAA Privacy Rules

11th Grade - Professional Development

20 Qs

MSDGN CHAPITRES 8 ET 9

MSDGN CHAPITRES 8 ET 9

1st Grade - University

20 Qs

QUY ĐỊNH RIÊNG ĐỐI VỚI LAO ĐỘNG ĐẶC THÙ

QUY ĐỊNH RIÊNG ĐỐI VỚI LAO ĐỘNG ĐẶC THÙ

University

20 Qs

Биология 20 сұрақ

Биология 20 сұрақ

University

20 Qs

PIM PERTEMUAN 1

PIM PERTEMUAN 1

University

20 Qs

РО 4.5

РО 4.5

Assessment

Quiz

Specialty

University

Practice Problem

Easy

Created by

Heiネ Heiネ

Used 6+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

22 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where does the distillate from columns A-701A/B/C/D go?

Column C-701

Reactor unit D-702

Column C-601

Column D-701

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the purpose of pump P-907 in the described technological scheme?

To control the pressure in the discharge line of pump P-907.

To pump non-condensable product into the storage park

To release hydrocarbon gas into the emergency release tank D-903.

To control the temperature in tank D-903.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which parameter is controlled and recorded by position 900-PI-0501?

Fuel gas consumption for purging

Pressure of the product in tank D-909

Temperature of the product in tank D-909

Level of the product in tank D-909

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the purpose of the chiller unit PK-901 in the described technological scheme?

To supply coolant from the mobile vehicles to the D-914 coolant buffer tank.

To condense the blowdown gas in additional condensers E-656 and E-707.

To control the temperature at the inlet and outlet of the chiller unit.

To cool the coolant from 8 °C to 5 °C.

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which parameter is controlled and recorded by position 900-TIC-0104?

Pressure drop on the filters F-902A/B

Fuel gas pressure

Fuel gas consumption

Temperature of the fuel gas at the outlet of the E-902

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the purpose of valve V-602 in the system?

To shut down the entire system in case of emergency.

To regulate the flow rate of the feed stream into the reactor R-601.

To control the temperature of the product stream leaving the reactor R-601.

To prevent backflow from the paraxylene concentration column C-604 to the mixing tank D-607.

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the function of pumps P-609A/B in the system?

They shut down the entire system when the maximum flow rate is reached.

They adjust the pressure of the circulating product.

They control the flow rate at the inlet of pump P-606 A/C.

They supply liquid for irrigation of the paraxylene concentration column C-604.

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?