HEAR 657 Term 4 Chapter 2

HEAR 657 Term 4 Chapter 2

University

6 Qs

quiz-placeholder

Similar activities

How to make a cake

How to make a cake

6th Grade - Professional Development

8 Qs

Malaysia Sustainable Issues: Sustainable Development Goals

Malaysia Sustainable Issues: Sustainable Development Goals

University - Professional Development

11 Qs

CCHU5001_Week 3_Quiz

CCHU5001_Week 3_Quiz

University

10 Qs

Tipos de alimentos (Resolución 2674 de 2013)

Tipos de alimentos (Resolución 2674 de 2013)

University

10 Qs

CHAPTER 6 : TOOLs AND TECHNIQUES FOR PROCESS IMPROVEMENT

CHAPTER 6 : TOOLs AND TECHNIQUES FOR PROCESS IMPROVEMENT

University

10 Qs

Inline Homework 3

Inline Homework 3

University - Professional Development

10 Qs

Optical Fiber Communication - Basics

Optical Fiber Communication - Basics

University

10 Qs

Post Test

Post Test

University

11 Qs

HEAR 657 Term 4 Chapter 2

HEAR 657 Term 4 Chapter 2

Assessment

Quiz

Other

University

Medium

Created by

Ziva Shai Campbell

Used 10+ times

FREE Resource

6 questions

Show all answers

1.

MULTIPLE SELECT QUESTION

45 sec • 1 pt

Which statement(s) is/are true about testbox measures?

They tell you how well the HA is meeting prescription targets.

They tell you if the HA is performing like the manufacturer said it would.

You should use an HA-1 coupler with BTEs.

You should use a CIC coupler for CICs.

2.

MULTIPLE SELECT QUESTION

45 sec • 1 pt

Which statement(s) is/are true of the ANSI standard for testbox measurements?

The HFA frequencies are 1000, 1500, and 2000 Hz.

The peak (max) OSPL90 should not be > 3 dB from the specs.

The THD at 500 Hz should not be >3% of the specs.

The EIN should not be > 3 dB of the specs.

3.

MULTIPLE SELECT QUESTION

45 sec • 1 pt

Which statement(s) is/are true of real-ear (probe microphone) measurements?

They tell you how well the HA is meeting the prescription targets.

The tell you if the HA is performing like the manufacturer said it would.

They should be done in a sound-isolating booth.

You need to calibrate before each measurement.

4.

MULTIPLE SELECT QUESTION

45 sec • 1 pt

Which real-ear measurement represents the natural amplification provided by the ear canal?

REAR

REUG

REIG

REUR

5.

MULTIPLE SELECT QUESTION

45 sec • 1 pt

Which component(s) below is/are part of CORFIG?

Unaided gain of client's ear

Gain of the HA

Residual volume effects of coupler

Microphone location

6.

MULTIPLE SELECT QUESTION

45 sec • 1 pt

Media Image

Which statement(s) is/are true about this image?

The HA gain needs to be decreased to hit targets.

The HA gain needs to be increased to hit targets.