1.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Hole filling fasteners (for example, MS20470 rivets) should not be used in composite structures primarily because of the

possibility of causing delamination

increased possibility of fretting corrosion in the fastener

difficulty in forming a proper shop head

2.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

The point at which freon flowing through a vapor-cycle cooling system gives up heat and changes from a gas to a liquid is the

condenser

evaporator

expansion valve

3.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Which of the following, when added to wet resins, provide strength for the repair of damaged fastener holes in composite panels?

Flox and chopped fibers

microballoons

microballoons and flox

4.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

An airplane that has a tendency to gradually increase a pitching moment that has been set into motion has

poor longitudinal stability

good lateral stability

poor lateral stability

5.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Many fuel tanks incorporate _________________ valves to prevent fuel from flowing away from the boost pump or tank outlet when the aircraft is in a high 'G' maneuver.

flapper

check

dump

6.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

In some aircraft with several fuel tanks, the possible danger of allowing the fuel supply in one tank to become exhausted before the selector valve is switched to another tank is prevented by the installation of

a fuel pressure warning signal system

a fuel pressure relief valve

an engine fuel pump bypass valve

7.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Frost or ice buildup on a vapor-cycle cooling system evaporator would most likely be caused by

the mixing valve sticking closed

moisture in teh evaporator

inadequate airflow through the evaporator

Create a free account and access millions of resources