2021 Practice Test #2

2021 Practice Test #2

Professional Development

100 Qs

quiz-placeholder

Similar activities

Comprehensive Final Exam

Comprehensive Final Exam

Professional Development

100 Qs

GPM Exam 1 Review (part 1)

GPM Exam 1 Review (part 1)

Professional Development

105 Qs

ATL TINKER QUIZ 2021

ATL TINKER QUIZ 2021

Professional Development

103 Qs

Mining Law

Mining Law

Professional Development

102 Qs

Missouri FFA Knowledge

Missouri FFA Knowledge

Professional Development

100 Qs

REACTIVE

REACTIVE

Professional Development

103 Qs

Hitha C Quiz 1 Continue

Hitha C Quiz 1 Continue

Professional Development

99 Qs

DAY I--ALE JAN 2022

DAY I--ALE JAN 2022

Professional Development

100 Qs

2021 Practice Test #2

2021 Practice Test #2

Assessment

Quiz

Other

Professional Development

Medium

Created by

Mike Sommerfeldt

Used 7+ times

FREE Resource

100 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Heating, cooling ventilating a process systems serving spaces or providing healthcare functions, shall be provided in accordance with __________.

NFPA 55

ASSE 6000

NFPA 99

ASHRAE 170

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where existing, the portion of the supply equipment that automatically supplies the system, when the primary and secondary are unable.

Back-up source

Secondary source

Emergency supply

Reserve supply

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

For the purposes of this code, an oxygen enriched atmosphere is an atmosphere where the total concentration of oxygen exceeds ________ by volume.

23.5%

23.6%

19.5%

93%

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

It is NOT permissible to pipe & utilize medical gases such as oxygen for which of these purposes?

Direct respiration by patients

General utility, such as moisture removal from instruments

Operating medical equipment that is only intended for patient use

Simulation centers for the assessment of healthcare specialists

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Cylinders in use and in storage shall be prevented from reaching temperatures in excess of ________.

120º F

125º F

130º F

150º F

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Central supply systems, located outdoors, shall meet all EXCEPT which of the following requirements?

Allow for clear access for the management of cylinders

Be greater than 200 square feet

Be provided with an enclosure constructed of noncombustible material

Be well drained

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Pressure relief valves shall meet which of the following requirements?

Constructed of brass or bronze

Shall have the pressure relief setting not more than 5 percent higher than the maximum allowable working pressure of the system served

They may discharge in unoccupied rooms

They shall be designed for the specific gas service

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?