Day 1 AP-GRAS Seminar

Day 1 AP-GRAS Seminar

Professional Development

20 Qs

quiz-placeholder

Similar activities

organisation of data

organisation of data

11th Grade - Professional Development

20 Qs

Torque Converter

Torque Converter

Professional Development

19 Qs

Battle Cats

Battle Cats

Professional Development

25 Qs

Merc Switches Quiz 01 (JE)

Merc Switches Quiz 01 (JE)

Professional Development

17 Qs

Science Partial Quiz Trim III

Science Partial Quiz Trim III

Professional Development

15 Qs

CNE- Hepatobiliary Workshop

CNE- Hepatobiliary Workshop

Professional Development

15 Qs

Con te partiro

Con te partiro

Professional Development

16 Qs

OME Quiz 1

OME Quiz 1

Professional Development

16 Qs

Day 1 AP-GRAS Seminar

Day 1 AP-GRAS Seminar

Assessment

Quiz

Other

Professional Development

Medium

Created by

S R

Used 6+ times

FREE Resource

20 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the design principle a Measurement Microphone is based on?

Carbon Microphone Principle

Dynamic Microphone Principle

Ribbon Microphone Principle

Condenser Microphone Principle

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the output of a Measurement Microphone?

It´s a current output proportional to the pressure fluctuation obtained by the diaphragm 

It´s a voltage output proportional to the pressure fluctuation obtained by the diaphragm 

It´s a charge output proportional to the pressure fluctuation obtained by the diaphragm 

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the maximum output voltage swing of CCP Microphone Sets?

28 V peak - peak

8 V peak

13 V peak - peak

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the microphone polarization voltage required from the DAQ/Analyzer to drive a pre-polarized microphone set?

+200 VDC

+100 VDC

0 VDC

+200 VAC

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The larger the diaphragm of the microphone is...

The lower the sensitivity and the higher the frequency range

The higher the sensitivity and lower frequency range

The size of a microphone´s diaphragm has nothing to do with the sensitivity and frequency range

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is a WS3F measurement microphone?

It´s a 3" working standard measurement microphone according to IEC 61094

It´s a 1/2" working standard free-field microphone according to IEC 61094

It´s a 1/4" working standard free-field microphone according to IEC 61094

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

. What will happen with the frequency response if you have a lot of dirt and dust on the diaphragm?

The upper cut-off frequency will increase

The upper cut-off frequency will decrease

Nothing will happen, as the mass of the diaphragm is 100 times higher than the mass of the dirt and dust

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?