Medical Gas Systems 2021 1-25

Medical Gas Systems 2021 1-25

Professional Development

25 Qs

quiz-placeholder

Similar activities

2018 IPC CH 3A Study Quiz

2018 IPC CH 3A Study Quiz

Professional Development

25 Qs

2018 IFGC CH 5B

2018 IFGC CH 5B

Professional Development

25 Qs

2018 IPC CH 1 Study Quiz

2018 IPC CH 1 Study Quiz

Professional Development

25 Qs

2018 IFGC CH 3A

2018 IFGC CH 3A

Professional Development

25 Qs

2018 IPC CH 11-14 Study Quiz

2018 IPC CH 11-14 Study Quiz

Professional Development

25 Qs

91F Statement of utilisation of funds

91F Statement of utilisation of funds

Professional Development

20 Qs

2018 IPC CH 9B Quiz

2018 IPC CH 9B Quiz

Professional Development

25 Qs

2018 IPC CH 3A Study Quiz

2018 IPC CH 3A Study Quiz

Professional Development

25 Qs

Medical Gas Systems 2021 1-25

Medical Gas Systems 2021 1-25

Assessment

Quiz

Other

Professional Development

Hard

Created by

Johnny Thulin

Used 4+ times

FREE Resource

25 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

An existing system that is not in strict compliance with the provisions of this code shall be permitted to be continued in use as long as the _______ has determined that such use does not constitute a distinct hazard to life.
A. architect
B. nursing staff
C. engineer
D. authority having jurisdiction

2.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Cylinder and cryogenic liquid container outlet connections shall be affixed in such a manner as to be intregal to the valve, unremovable with ordinary tools or so designed as to render the attachment point ________ when removal of the outlet connection is attempted.
A. reusable
B. universal
C. unsuitable
D. unusable

3.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Which of the following systems shall not be permitted to be located in an outdoor enclosure?
A. Manifolds for gas cylinders
B. Manifolds for cryogenic liquid containers
C. Medical air compressor sources
D. Bulk cryogenic liquid systems

4.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

What is required of the alarm system if another alarm condition occurs while the audible alarm is manually silenced?
A. Nothing, the visual indicator is still active
B. The visual indicator must blink
C. The audible signal will beep
D. Re-initiation of the audible signal

5.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Cylinders in use and in storage shall be prevented from reaching temperatures in excess of ____________.
A. 120ºF
B. 125ºF
C. 130ºF
D. 150ºF

6.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Locations for central supply systems shall have electrical devices protected from ___________.
A. unauthorized use
B. physical damage
C. freezing temperatures
D. moisture

7.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Mechanical exhaust for central supply locations shall not be more than ____.
A. 50 cfm
B. 72 cfm
C. 100 cfm
D. 500 cfm