1.
MULTIPLE SELECT QUESTION
45 sec • 1 pt
Which of the following are the suitable NDE methods to measure thickness?
UT
Profile RT
MT
PT
2.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is D in this formula?
Uncorroded inside diameter
Corroded inside diameter
Uncorroded outside diameter
Corroded outside diameter
3.
MULTIPLE SELECT QUESTION
45 sec • 1 pt
Which suitable UT methods can be used to measure thickness on coated surface? (2 methods)
Remove coat before taking measurement with valid calibration
Measure directly on surface with no coat calibration
Use through-coat setting when measuring after calibration
Use two point calibration method
4.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What do you call a pipe without weld seam?
Welded pipe
Unwelded pipe
Unseam pipe
Seamless pipe
5.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is normally E value for seamless pipe?
0.7
0.9
0.85
1.0
6.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the meaning of symbol E in this formula?
Joint efficiency
Weld effectivity
Weld rating
NDT extent
7.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the liquid used in UT to enable ultrasonic wave to propagate into the test specimen?
Coupler
Couplant
Transfer gel
Lubricant