HVAC 104

HVAC 104

Professional Development

20 Qs

quiz-placeholder

Similar activities

Fundamental of Common Rail Diesel Fuel System

Fundamental of Common Rail Diesel Fuel System

University - Professional Development

15 Qs

Best Mechanic Of the Month Januari 2025

Best Mechanic Of the Month Januari 2025

Professional Development

20 Qs

Aerodynamic Drag Yr10 Engineering

Aerodynamic Drag Yr10 Engineering

10th Grade - Professional Development

18 Qs

Aerodynamic Lift Yr10 Engineering

Aerodynamic Lift Yr10 Engineering

10th Grade - Professional Development

20 Qs

Scratch: Events, Loops and The Coordinate System

Scratch: Events, Loops and The Coordinate System

2nd Grade - Professional Development

15 Qs

AUT 101 Engine Repair 1 Week 2 quiz

AUT 101 Engine Repair 1 Week 2 quiz

Professional Development

20 Qs

Security Plus 1-02

Security Plus 1-02

Professional Development

20 Qs

CONTROL  INTERNO- COSO

CONTROL INTERNO- COSO

1st Grade - Professional Development

16 Qs

HVAC 104

HVAC 104

Assessment

Quiz

Instructional Technology

Professional Development

Medium

Created by

Jamey Amparo

Used 5+ times

FREE Resource

20 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A TXV with a liquid charged bulb is usually limited to ____________.

high temperature applications

applications where the ambient air temperature stays above freezing

applications that have a narrow operating range

systems that operate below atmospheric pressure

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the primary function of a TXV in a refrigeration system?

To control the flow of refrigerant into the evaporator

To control the temperature of the refrigerant

To control the pressure of the refrigerant

To control the humidity of the refrigerant

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What could be a possible issue if a TXV is not properly adjusted?

The refrigerant flow could be too high, causing the evaporator to flood

The refrigerant flow could be too low, causing the evaporator to starve

Both A and B

None of the above

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What type of charge is used in a TXV with a gas charged bulb?

High temperature applications

Applications where the ambient air temperature stays above freezing

Applications that have a narrow operating range

Systems that operate below atmospheric pressure

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The spring tension on a TXV is factory set for a predetermined superheat of _____ °F.

8-12

10-20

3-6

8-16

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Any evaporator that operates below 32°F ______________.

needs a thermostat

does not need defrost

requires some form of defrost

no such thing

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Refrigerant relief valves come in two different types, ___________.

spring loaded and double tap

Spring loaded and one time

fixed or variable

expensive and cheap

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?