Domestic Gas Ventilation Quiz

Domestic Gas Ventilation Quiz

Professional Development

10 Qs

quiz-placeholder

Similar activities

Mixed bank

Mixed bank

KG - Professional Development

7 Qs

Mengukur Luas Permukaan Sekata

Mengukur Luas Permukaan Sekata

Professional Development

13 Qs

diabetes

diabetes

10th Grade - Professional Development

14 Qs

ACS CCN1 Quiz 4

ACS CCN1 Quiz 4

Professional Development

7 Qs

Biosafety principle

Biosafety principle

Professional Development

8 Qs

Phase4.mod13.chimney test

Phase4.mod13.chimney test

Professional Development

7 Qs

Ulangan Harian 1

Ulangan Harian 1

Professional Development

10 Qs

8710 unit 6 ppt 4

8710 unit 6 ppt 4

Professional Development

13 Qs

Domestic Gas Ventilation Quiz

Domestic Gas Ventilation Quiz

Assessment

Quiz

Science

Professional Development

Medium

Created by

John Flower

Used 7+ times

FREE Resource

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When converting Gross heat input to net heat input you must?

Multiply by 1.11.

Divide by 1.11.

Divide by 1.09.

Multiply by 1.08.

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the equivalent net kW figure for adventitious air?

14 kW.

28 kW.

1.11 kW.

7 kW.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When calculating compartment ventilation we must not make any allowances for?

For low level ventilation.

For high level ventilation.

For adventitious ventilation.

All of the above.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the smallest size of opening allowed in a vent used for supplying combustion air?

5 mm.

6 mm.

9 mm.

10 mm.

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Vents supplying combustion air to a gas fired appliance passing through a cavity wall must be?

At least 100 mm2 cross sectional area.

Sleeved/ducted throughout the width of the wall.

Painted yellow ochre to identify it as a gas vent.

At least 50% larger than the actual requirement.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

If a gas cooker requires ventilation it must be?

Provided at high and low levels within the same room as the cooker.

Sized in accordance the manufacturer's instructions or BS 5440-2.

Provided indirectly so as to reduce draughts.

Sized in accordance with BS 5440-1.

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When determining the ventilation requirements for an open flued gas appliance within a room, it is derived from?

Heat input gross - 7 x 5 (cm2/kW).

Heat input net - 7 x 4.5 (cm2/kW).

Heat input net - 7 x 5 (cm2/kW).

Heat input gross - 7 x 4.5 (cm2/kW).