EPA Type III New Quiz

EPA Type III New Quiz

12th Grade

61 Qs

quiz-placeholder

Similar activities

type of accommodation and hotel room

type of accommodation and hotel room

KG - Professional Development

59 Qs

Berry Selection and Storage Quiz

Berry Selection and Storage Quiz

12th Grade

64 Qs

Tvd

Tvd

KG - Professional Development

59 Qs

credit reports and scores

credit reports and scores

9th - 12th Grade

61 Qs

Ch. 15 Virtuality and Teamwork

Ch. 15 Virtuality and Teamwork

12th Grade

62 Qs

FAA Part 107 quick review

FAA Part 107 quick review

10th Grade - Professional Development

60 Qs

Dog Breeds

Dog Breeds

11th - 12th Grade

59 Qs

Review PPL

Review PPL

11th - 12th Grade

66 Qs

EPA Type III New Quiz

EPA Type III New Quiz

Assessment

Quiz

Professional Development

12th Grade

Medium

Created by

Kim Jackson

Used 5+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

61 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

1. A typical setting for the high pressure cut-out control on a recovery unit used for evacuating the refrigerant from a low pressure chiller is:

A) 2 psig.

B) 5 psig.

C) 10 psig.

D) 15 psig.

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

2. A charged low pressure refrigeration system can be efficiently leak checked by:

A) adding compressed air, since it will be removed from the system by the Purging unit.

B) operating the purge system.

C) adding HCFC-22.

D) raising system pressure by heating with circulated hot water or heating blankets.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

3. The existence of air in a low pressure system, causes __________.

A) low head pressure.

B) low suction pressure.

C) high head pressure.

D) high liquid level.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

4. Which safety precaution should be adhered to for low pressure systems?

A) Do not siphon refrigerant by mouth.

B) Avoid spilling liquid refrigerant on the skin.

C) Use gloves and safety goggles when working with liquid refrigerant.

D) all of the above

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

5. Refrigerant-11 at 14.7 PSIA will boil at about:

A) 60.3F.

B) 74.5F.

C) 79.7F.

D) 80.2F.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

6. When there is excessive moisture collecting in the purge unit of a low pressure refrigeration system, this indicates that the __________.

A) the system was charged with contaminated refrigerant.

B) the condenser or chiller barrel tubes are leaking.

C) the purge unit is not operating properly.

D) the purge unit needs adjustment.

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

7. ASHRAE Standard 15 - 1994 requires equipment room refrigerant sensors for what safety group classification? A) A1 B) B2 C) A2 D) All refrigerant safety groups

A) A1

B) B2

C) A2

D) All refrigerant safety groups

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?

Discover more resources for Professional Development