EMPS QUIZ 2

EMPS QUIZ 2

University

10 Qs

quiz-placeholder

Similar activities

"Review of the Basic Electrical Engineering "

"Review of the Basic Electrical Engineering "

University

15 Qs

Grounding System

Grounding System

12th Grade - University

15 Qs

control system

control system

University

10 Qs

Power System Quiz

Power System Quiz

University

10 Qs

Transistors

Transistors

University

10 Qs

POWER SYSTEM 1 TOPIC 1 PART 1

POWER SYSTEM 1 TOPIC 1 PART 1

University

15 Qs

Alternating Current

Alternating Current

University

10 Qs

FORMATIVE ASSESSMENT TOPIC 6

FORMATIVE ASSESSMENT TOPIC 6

University

10 Qs

EMPS QUIZ 2

EMPS QUIZ 2

Assessment

Quiz

Other

University

Medium

Created by

Hemalatha G

Used 4+ times

FREE Resource

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The distribution in residential areas are 

  • Single phase, two-wire

Three phase, three-wire

Three phase, four-wire

Two phase, four-wire 

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The conductor of an EHV line is selected on the basis of 

Current carrying capacity

Corona and RI performance

Line voltage

None of these

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Series capacitive compensation in EHV transmission lines is used to 

Reduce the line loading 

Improve the stability of the system

Reduce the voltage profile

Improve the protection of the line

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In a dc transmission line

It is necessary for the sending end and receiving end to be operated in synchronism.

The effects of inductive and capacitive reactance?s are greater than in an ac transmission line of the same rating.

There are no effects due to inductive and capacitive and capacitive reactance

Power transfer capability is limited by stability considerations.

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Bulk power transmission over long High Voltage DC lines is preferred because of

Low cost of HVDC terminal.

No harmonic losses.

Minimum line power losses

Simple protection. Simple protection. 

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

11.High Voltage DC monopolar link uses

One conductor usually of negative polarity

One conductor usually of positive polarity

Two conductor one of positive and the other of negative polarity

Two conductors both of negative polarity

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Back to back High Voltage DC is used to

Increase the transmission capability

Decrease line losses

  • Provide stable interconnection

  • D

  • Reduce voltage drop

Answer / Hint