Underground piping shall be permitted to extend into the building through the slab or wall not more than ____ inches.

Monthly Code Quiz March

Quiz
•
Professional Development
•
Professional Development
•
Hard
Robert Starcher
Used 15+ times
FREE Resource
10 questions
Show all answers
1.
FILL IN THE BLANK QUESTION
15 mins • 10 pts
2.
FILL IN THE BLANK QUESTION
15 mins • 10 pts
What section number states, "The top of the pipe shall be buried not less than 1 ft below the frost line for the locality.
Hint= Answer is 5 numbers long _._._._._
3.
MULTIPLE CHOICE QUESTION
15 mins • 10 pts
Drop-out ceilings and ceiling materials shall not be installed below quick-response or extended coverage sprinklers unless __________.
the sprinklers are only upright type
specifically listed for that application
the sprinklers are less than 12" above the ceilings
the ceilings are less than 32 ft² in size
4.
FILL IN THE BLANK QUESTION
15 mins • 10 pts
Which section number states, "System components shall be rated for the maximum system working pressure to which they are exposed but shall not be rated at less than 175 psi for components installed above ground and 150 psi for components installed underground." Hint = Answer is 3 numbers long _._._
5.
MULTIPLE CHOICE QUESTION
15 mins • 10 pts
The underground pipe supply for a pipe schedule system shall be______.
No smaller than 6”
At least as large as the FDC piping
4” or larger
At least as large as the system riser
6.
FILL IN THE BLANK QUESTION
15 mins • 10 pts
When installing a standard pendent or upright spray sprinkler, which section number states "Sprinklers shall be installed under fixed obstructions over 4 ft wide." Hint= Answer is 5 numbers long _._._._._
Answer explanation
Sprinklers shall be installed under fixed obstructions over 4 ft (1.2 m) wide
While you may find the same answer in 10.3.6.3.2*
Sprinklers shall be installed under fixed obstructions over 4 ft wide
Section 10.3 refers to Sidewall Standard Spray Sprinklers
7.
MULTIPLE CHOICE QUESTION
15 mins • 10 pts
Fire department connections shall be located at the nearest point of fire department apparatus accessibility or at a location approved by the ________.
AHJ
designer
building owner
installer
Create a free account and access millions of resources
Similar Resources on Wayground
10 questions
Air Supplies

Quiz
•
Professional Development
13 questions
6035 | Drainage systems | LO1.1

Quiz
•
Professional Development
10 questions
L2 Common Plumbing Processes PT1

Quiz
•
University - Professi...
14 questions
T level BSE Heating

Quiz
•
University - Professi...
10 questions
Cold Water Systems LO5

Quiz
•
Professional Development
13 questions
Zechariah Chapter 12

Quiz
•
Professional Development
13 questions
Cold Water Systems LO2

Quiz
•
Professional Development
10 questions
Monthly Code Quiz July

Quiz
•
Professional Development
Popular Resources on Wayground
25 questions
Equations of Circles

Quiz
•
10th - 11th Grade
30 questions
Week 5 Memory Builder 1 (Multiplication and Division Facts)

Quiz
•
9th Grade
33 questions
Unit 3 Summative - Summer School: Immune System

Quiz
•
10th Grade
10 questions
Writing and Identifying Ratios Practice

Quiz
•
5th - 6th Grade
36 questions
Prime and Composite Numbers

Quiz
•
5th Grade
14 questions
Exterior and Interior angles of Polygons

Quiz
•
8th Grade
37 questions
Camp Re-cap Week 1 (no regression)

Quiz
•
9th - 12th Grade
46 questions
Biology Semester 1 Review

Quiz
•
10th Grade