What is initial verification according to the regulations?

Electrical Inspection and Testing Quiz

Quiz
•
Other
•
Professional Development
•
Medium
Dean Kirby
Used 3+ times
FREE Resource
15 questions
Show all answers
1.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
The final inspection and test on a new installation or a new circuit
The first inspection and test on a new installation or a new circuit
The inspection and test of an installation that is not new
The inspection and test of an existing installation or circuit
2.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What should be done on completion of the verification according to the regulations?
Prepare a list of defects for the customer
Prepare a certificate for the customer
Prepare a quotation for the customer
Prepare a report for the customer
3.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the minimum insulation resistance reading for a new installation?
Above 100 kilo ohms
Above 100 mega ohms
Above 1 mega ohm
Above 10 mega ohms
4.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the correct sequence of testing for an installation?
Insulation resistance, continuity of conductors, polarity, earth fault loop impedance
Polarity, insulation resistance, continuity of conductors, earth fault loop impedance
Continuity of conductors, insulation resistance, polarity, earth fault loop impedance
Continuity of conductors, polarity, insulation resistance, earth fault loop impedance
5.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the purpose of periodic testing according to the regulations?
To identify installation defects
To verify the installation before being put into service
To advise the client on the safety of the installation
To ensure the installation is safe for continued use
6.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What must an inspector not do according to the regulations?
Partially dismantle an installation in order to carry out an inspection and test
Advise the client that installations to previous editions of regulations are unsafe
Work on a dead circuit
Identify installation defects
7.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the process after an electrical installation condition report deems an installation unsatisfactory?
A list of defects and observations must be created
The installation must be isolated immediately
The installation must be declared satisfactory
The installation must be reinspected
Create a free account and access millions of resources
Similar Resources on Quizizz
10 questions
145-S26-Week 7 Quiz 1

Quiz
•
Professional Development
20 questions
Electrical Safety Quiz

Quiz
•
Professional Development
20 questions
Electrical Installation Testing and Inspection

Quiz
•
Professional Development
10 questions
18th edition part 3 mock 3

Quiz
•
Professional Development
20 questions
Basic Electricity

Quiz
•
Professional Development
10 questions
18th Edition part 1 mock 2

Quiz
•
Professional Development
20 questions
Introduction to Transmission Lines

Quiz
•
Professional Development
20 questions
MEN Refresher 2

Quiz
•
Professional Development
Popular Resources on Quizizz
15 questions
Character Analysis

Quiz
•
4th Grade
17 questions
Chapter 12 - Doing the Right Thing

Quiz
•
9th - 12th Grade
10 questions
American Flag

Quiz
•
1st - 2nd Grade
20 questions
Reading Comprehension

Quiz
•
5th Grade
30 questions
Linear Inequalities

Quiz
•
9th - 12th Grade
20 questions
Types of Credit

Quiz
•
9th - 12th Grade
18 questions
Full S.T.E.A.M. Ahead Summer Academy Pre-Test 24-25

Quiz
•
5th Grade
14 questions
Misplaced and Dangling Modifiers

Quiz
•
6th - 8th Grade