Search Header Logo

Electrical Inspection and Testing Quiz

Authored by Dean Kirby

Other

Professional Development

Used 5+ times

Electrical Inspection and Testing Quiz
AI

AI Actions

Add similar questions

Adjust reading levels

Convert to real-world scenario

Translate activity

More...

    Content View

    Student View

15 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is initial verification according to the regulations?

The final inspection and test on a new installation or a new circuit

The first inspection and test on a new installation or a new circuit

The inspection and test of an installation that is not new

The inspection and test of an existing installation or circuit

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What should be done on completion of the verification according to the regulations?

Prepare a list of defects for the customer

Prepare a certificate for the customer

Prepare a quotation for the customer

Prepare a report for the customer

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the minimum insulation resistance reading for a new installation?

Above 100 kilo ohms

Above 100 mega ohms

Above 1 mega ohm

Above 10 mega ohms

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the correct sequence of testing for an installation?

Insulation resistance, continuity of conductors, polarity, earth fault loop impedance

Polarity, insulation resistance, continuity of conductors, earth fault loop impedance

Continuity of conductors, insulation resistance, polarity, earth fault loop impedance

Continuity of conductors, polarity, insulation resistance, earth fault loop impedance

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the purpose of periodic testing according to the regulations?

To identify installation defects

To verify the installation before being put into service

To advise the client on the safety of the installation

To ensure the installation is safe for continued use

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What must an inspector not do according to the regulations?

Partially dismantle an installation in order to carry out an inspection and test

Advise the client that installations to previous editions of regulations are unsafe

Work on a dead circuit

Identify installation defects

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the process after an electrical installation condition report deems an installation unsatisfactory?

A list of defects and observations must be created

The installation must be isolated immediately

The installation must be declared satisfactory

The installation must be reinspected

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?