1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

What is the first step in preparing to install a new furnace?

The first step is to determine the appropriate location.

Find the correct size of system

Test the breakers

Take a smoke break 15 min before you start

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

What is the difference between natural gas and propane?

Natural gas is mostly methane and a little ethane, has a specific gravity 0.6, and a heat capacity around 1000 BTU/hr. Propane has a specific gravity of 1.5 and a heat capacity of 2500 BTU/hr

Usually Natural GAS is adjusted at the gas valve to 3.8 " W.C.

Usually Propane is adjust at the gas valve to 11.6 " W.C.

Natural Gas smells like a rotten egg

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

What is the most common manifold pressure for natural gas furnaces?

3.5 inches WC

10 inches WC

5 inches WC

higher the pressure the higher the gas bill

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

What is the most common manifold pressure for propane furnaces?

11 inches WC

3.5 inches WC

5 inches WC

Propane allows you too cook on your furnace while heating your home

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

A technician is clocking the gas usage of a gas furnace. It takes 30 seconds for the 1/2-foot dial to make 1 revolution. What is the rate of gas flow in cubic feet per hour?

60 cubic feet per hour

20 cubic feet per hour

10 cubic feet per hour

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Use the gas flow rate calculated from question 5 to determine the input in BTU/hr if the heating capacity of the gas is 950 BTU/ft3.

yep

60 cubic feet x 950 BTU/cubic foot = 57,000 BTUs per hour

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

What is the correct vent size for a 50,000 BTU/hr input induced draft furnace with a 15-foot lateral run and a 30-foot vent height?

3” or 4”

6" or 8"

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?