1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt


A unit of an electrical system, other than a conductor, that carries or controls electrical energy as its principal function is best defined as   ?  .

a device

electrical equipment

a sign

energized

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following best defines the circuit conductors between the final overcurrent protective device and the outlet(s)?

branch circuit

electrical wiring

feeder

supplemental branch circuit

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A _____ is generally not considered an outlet by the NEC.

device box with a 3-way switch

box with a surge-protective device (SPD) receptacle

device box with a duplex receptacle

device box with a GFCI receptacle

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where a device box is installed in a wall or ceiling that has a finish surface made of gypsum wallboard, what is the maximum distance that the face of the box or plaster ring is permitted to be set back from the finish?

1/4"

1/2"

3/8"

no set back permitted

Answer explanation

314.20

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The maximum gap permitted between drywall and the edge of a device box or plaster ring shall not be greater than _____.

1/8"

1/4"

2"

3/8"

Answer explanation

314.21

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where the branch circuit wiring is installed (fished) in existing hollow spaces of walls or ceilings, the device boxes are required to be secured to the _____.

finished surface

metal framing member of the wall or ceiling

wood framing member of the wall or ceiling

internal framing supports

Answer explanation

314.23(C)

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When determining conductor fill (volume allowances) at device boxes, branch circuit conductors that pass through a device box without a splice or termination are required to be counted in accordance with which of the following volume allowances?

each conductor must be counted once

all must be counted as one conductor

they are not required to be counted

Answer explanation

314.16(B)(1)

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?