CSP1 Lesson 8

CSP1 Lesson 8

Professional Development

12 Qs

quiz-placeholder

Similar activities

NEC Code Practice Test

NEC Code Practice Test

Professional Development

16 Qs

Virtualization Technologies - Day 1

Virtualization Technologies - Day 1

Professional Development

10 Qs

Chapter 40

Chapter 40

9th Grade - Professional Development

15 Qs

AMQ - Product of the Month

AMQ - Product of the Month

Professional Development

12 Qs

18th Edition Part 6 Mock 2

18th Edition Part 6 Mock 2

Professional Development

10 Qs

LOTOTO QUIZ

LOTOTO QUIZ

Professional Development

10 Qs

Electrical Safety

Electrical Safety

Professional Development

8 Qs

Diodes

Diodes

Professional Development

9 Qs

CSP1 Lesson 8

CSP1 Lesson 8

Assessment

Quiz

Other

Professional Development

Hard

Created by

Travis Webb

FREE Resource

12 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt


A unit of an electrical system, other than a conductor, that carries or controls electrical energy as its principal function is best defined as   ?  .

a device

electrical equipment

a sign

energized

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following best defines the circuit conductors between the final overcurrent protective device and the outlet(s)?

branch circuit

electrical wiring

feeder

supplemental branch circuit

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A _____ is generally not considered an outlet by the NEC.

device box with a 3-way switch

box with a surge-protective device (SPD) receptacle

device box with a duplex receptacle

device box with a GFCI receptacle

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where a device box is installed in a wall or ceiling that has a finish surface made of gypsum wallboard, what is the maximum distance that the face of the box or plaster ring is permitted to be set back from the finish?

1/4"

1/2"

3/8"

no set back permitted

Answer explanation

314.20

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The maximum gap permitted between drywall and the edge of a device box or plaster ring shall not be greater than _____.

1/8"

1/4"

2"

3/8"

Answer explanation

314.21

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where the branch circuit wiring is installed (fished) in existing hollow spaces of walls or ceilings, the device boxes are required to be secured to the _____.

finished surface

metal framing member of the wall or ceiling

wood framing member of the wall or ceiling

internal framing supports

Answer explanation

314.23(C)

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When determining conductor fill (volume allowances) at device boxes, branch circuit conductors that pass through a device box without a splice or termination are required to be counted in accordance with which of the following volume allowances?

each conductor must be counted once

all must be counted as one conductor

they are not required to be counted

Answer explanation

314.16(B)(1)