106 - 140 PRETTY HARD

106 - 140 PRETTY HARD

Professional Development

35 Qs

quiz-placeholder

Similar activities

Review Questions for PHIL. CONS.

Review Questions for PHIL. CONS.

7th Grade - Professional Development

33 Qs

Are you smarter than a fourth grader?

Are you smarter than a fourth grader?

KG - Professional Development

38 Qs

Unit 4 Study Guide

Unit 4 Study Guide

Professional Development

34 Qs

141 - 175

141 - 175

Professional Development

35 Qs

246 - 280

246 - 280

Professional Development

35 Qs

211 - 245

211 - 245

Professional Development

35 Qs

316 - 350

316 - 350

Professional Development

35 Qs

281 - 315

281 - 315

Professional Development

35 Qs

106 - 140 PRETTY HARD

106 - 140 PRETTY HARD

Assessment

Quiz

Social Studies

Professional Development

Easy

Created by

pgfyi fernandobrasil@p2e.com.br

Used 4+ times

FREE Resource

35 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the minimum required fire protecon rang for a fire window located in a ½-hour fire-resistance-rated fire paron?

0, no rang is required

20 minutes

30 minutes

45 minutes

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which one of the following classes of standpipe systems is intended primarily for the use of building occupants or the fire department during inial response?

Class I

Class II

Class III

Class IV

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Fans within the building shall be shown on the fire fighter's control panel. Status indicators shall be provided for all smoke control equipment, annunciated by fan and zone, when the yellow color has been displayed at the device it is meaning?

Fans, dampers and other operang equipment in their normal status.

Fans, dampers and other operang equipment in their off or closed status.

Fans, dampers and other operang equipment in their on or open status.

Fans, dampers and other operang equipment in a fault status.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In a Group A-2 occupancy, an automac sprinkler system shall be provided throughout any fire area having a minimum occupant load of ________.

50

60

100

3,000

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where woodworking operaons in a Group F-1 occupancy generate finely divided combusble waste, an automac sprinkler system is required where such operaons occupy a minimum size floor area of ________ square feet.

1,001

2,501

5,001

12,001

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

An automac sprinkler system shall be provided throughout a building with a Group M fire area located a minimum of ________ stories above grade plane.

2

3

4

6

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A building shall be fully sprinklered where the combined area of all Group S-1 fire areas exceeds ________ square feet.

2,000

5,000

12,000

24,000

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?