1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

On mini-split systems both refrigerant lines must be insulated because they are both:

Low pressure and low temperature in the heating mode.

Low pressure and low temperature in the cooling mode.

Low pressure and low temperature in the heating and cooling mode.

Low pressure and high temperature in the cooling mode.

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The refrigerant lines for single zone mini-split air conditioners are usually connected by:

SAE compression fittings.

Brazed connections.

Flare fittings.

Reflok fittings.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following is NOT a type of indoor unit used on mini-split systems?

Wall mount

Ceiling suspended

Floor mount

Crawl space

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Power for the mini-split system is supplied:

To the outdoor unit which powers the indoor unit.

To the indoor unit which powers the outdoor unit.

 To the indoor and outdoor with their own separate dedicated wiring and circuit protection.

Any of these methods may be used.

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Designing a heating and cooling system to accommodate load shifts:

Allows buildings to operate with less installed capacity and still meet the demand.

Improves comfort.

Improves efficiency.

All of the above.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

Variable refrigerant flow systems use:

Inverter driven systems and thermostatic expansion valves.

Inverter driven systems and electronic expansion valves.

Scroll compressors and electronic expansion valves.

Scroll compressors and thermostatic expansion valves.ee

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

A type system that allows simultaneous heating and cooling to different parts of a building is the:

Multisplit system.

Heat pump variable refrigerant flow system.

Heat recovery system.

All of the above.

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?